Description: IMC board compression image store memory error Access error of IMC standard compression memory
Causes: IMC board abnormality
Remedy: Replace the IMC PWB.
Code: E1-17
Description: IMC board smoothing IC error IMC smoothing IC abnormality
Causes: IMC board abnormality
Remedy: Replace the IMC PWB.
Code: E1-80
Description: IMC PWB communication trouble (protocol) Communication trouble between MCU and IMC PWB (Protocol error)
Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
Code: E1-81
Description: IMC PWB communication trouble (Parity) Communication trouble between MCU and printer IMC (Parity error)
Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
Code: E1-82
Description: IMC PWB communication trouble (Overrun) Communication trouble between MCU and IMC PWB (Overrun error)
Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
Code: E1-84
Description: IMC PWB communication trouble (Framing) Communication trouble between MCU and IMC PWB (Framing error)
Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
Code: E1-88
Description: IMC PWB communication trouble (Timeout) Communication trouble between MCU and IMC PWB (Time-out error)
Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
Code: E7-02
Description: LSU trouble BD signal from LSU is not detected in a constant cycle. (Kept OFF or ON)
Causes: LSU connector or LSU inside harness trouble or disconnection Polygon motor rotation abnormality Laser does not illuminate. MCU PWB failure
Remedy: Check for disconnection of the LSU connector. Check the LSU operation with SIM 61-1. Check that the polygon motor rotates normally. Check laser LED lighting. LSU replacement Replace the MCU PWB.