Description: While feeding from the MPF, the input sensor did not break.
Remedy: • Ensure proper media is set for the type of paper used. • Fan media, and stack it flat in the tray or MPF. • Properly set media restraints in the paper tray. • Check the pick arm rolls (tires) and replace if worn. • Replace the paper tray. • Replace the MPF swing arm assembly • If the previous actions do not fix the problem, replace the paper pick mechanism.
Description: While feeding from the MPF, the input sensor is made while the previous page is still in the aligner.
Remedy: • Ensure proper media is set for the type of paper used. • Fan media, and stack it flat in the tray or MPF. • Properly set media restraints in the paper tray. • Check the pick arm rolls (tires) and replace if worn. • Replace the paper tray. • Replace the MPF swing arm assembly. • If the previous actions do not fix the problem, replace the paper pick mechanism.
Description: While feeding from the MPF, the input sensor is not made.
Remedy: • Ensure proper media is set for the type of paper used. • Fan media, and stack it flat in the tray or MPF. • Properly set media restraints in the paper tray. • Check the pick arm rolls (tires) and replace if worn. • Replace the paper tray. • Models 205CP only: Replace the MPF swing arm assembly. • If the previous actions do not fix the problem, replace the paper pick mechanism.
Remedy: • Ensure proper media is set for the type of paper used. • Fan media, and stack it flat in the tray or MPF. • Replace the MPF swing arm assembly.