Remedy: RADF board • Check if the harness connecting the RADF board and SYS board is disconnected or open circuited. • Check if the conductor pattern on the RADF board is short circuited or open circuited. SYS board Check if the conductor pattern on the SYS board is short circuited or open circuited.
Code: C551
Description: Incorrect RADF installed to the equipment
Causes: RADF
Remedy: • Replace the RADF with the correct one.
Code: C560
Description: Communication error between Engine-CPUs. • Communication error between Engine-CPUs • Communication error between LGC-PFC
Description: RADF communication protocol abnormality. The system has to be stopped because the control abnormality occurred.
Causes: RADF board
Remedy: Power • Turn the power OFF and then back ON to check if the equipment operates normally. RADF board • Connector check Board check
Code: C900
Description: Connection error between the SYS board and the LGC board
Causes: LGC board If the problem is not corrected with the replacement of the LGC board, reinstall the removed LGC board and replace the SYS board. SYS board. Harness (Flat cable)