Remedy: 1 Does the exposure lamp lit? (Perform the output check: FS-03-267) Yes It is lit. 2 No It is not lit. 3 2 Shading correction plate Check if there is any scratch or stain on the shading correction plate. Mirror Check if the mirror is tilted. 1. Check that the lens is reflected in the mirror looking at carriage-1 from the upper position. 2. Check that the mirror is secured at the leaf spring. Carriage 1. Check if the carriage is tilted by moving it to the left stopping point. 2. Check if the wire fixing screw is loosened. 3. Check if the movement of the carriage is unstable due to disengagement of the carriage roller. LED 1. Check if the LED lamp is correctly lit. 2. Check if the harness is connected properly to the LED lamp connector. 3. When the carriage is driven, check if the harness interferes with it or parts are caught in it. CCD board / Lens unit 1. Check if the connector of the CCD board is connected properly. 2. Check if the CCD board is installed properly. (Check that the lens unit is not tilted or the screw is securely tighten.) SYS board 1. Check if the connector of the SYS board (CN120, CN123) is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if the power is output from the SYS board for CCD. 3 SYS board 1. Check if the supply cable is connected properly to the connector (CN125). 2. Check if the mounted parts on the SYS board are damaged or abnormal. LED 1. Check if the harness of the lamp is connected to the LED light source properly. 2. Check if the lamp is scratched or damaged. 3. Check if the LED harness comes off the board. Supply harness 1. Check if wiring of the supply harness (CN125) is abnormal. 2. Check if the harness is scratched or open circuited.
Remedy: 1 Lens unit 1. Check if the connector is properly connected all the way in the CCD board. (CN001) 2. Check if there is any abnormality in the appearance of parts mounted on the CCD board. 3. Check if +5V is output to the CCD board. 4. Check if +3.3V is output from the CCD board. 5. Replace the Lens unit. 2 SYS board 1. Check if the connector is properly connected all the way in the SYS board. (CN120) 2. Check if there is any abnormality in the appearance of parts mounted on the SYS board. 3. Check if +5V is output to the SYS board. 4. Replace the SYS board. 3 Harnesses 1. Check if the harness has any scratch on it or is open circuited or caught anywhere. 2. Check if there is any abnormality in the connector terminal or the contacting surface of the flat cable. 3. Replace the harness between the SYS board and the CCD board.
Code: C270
Description: Carriage home position sensor not going OFF within a specified time / Downloading firmware with an incorrect model
Causes: CCD board Carriage home position sensor Carriage home position sensor harness SYS board Scan motor Scan motor harness
Remedy: 1 Carriage locking Check if the carriage locking screw for packaging is attached. 2 Are the carriages slightly moved to the feeding direction?/Are the carriages staying at a position other than home position? Yes Check if the circuits of the CCD board are abnormal. No 3 3 CCD board ¡E Check if the connector pin is disconnected or the harness is short circuited or open circuited. ¡E Check if the conductor pattern on the CCD board is short circuited or open circuited. ¡E If the model of the firmware downloaded is incorrect, a C270 error (exposure lamp blinks twice) occurs. If the exposure lamp blinks twice, download the correct firmware. 4 Carriage home position sensor 1. Check if the harness of the carriage home position sensor is connected properly. 2. Check if the harness is caught or open circuited. 5 SYS board 1. Check if the connector of the SYS board (CN121, CN124, CN125) is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24 V (CN125) on the SYS board is short circuited. 4. Check if 24 V is supplied to the SYS board (CN125). 6 Scan motor 1. Check if the belt tension is loosened. 2. Check if the motor fixing screw is loosened. 3. Check if the carriage wire and the timing belt come off. 4. Check if the connector (CN124) is connected to the motor properly. 5. Check if the harness of the motor is caught or open circuited. 7 Setting Clear the SRAM data and initialize them. Refer to ƒt P. 9-24 "9.2.5 Precautions and procedure when replacing the SRAM".
Code: C280
Description: Carriage home position sensor not going ON within a specified time
Causes: Carriage home position sensor Carriage home position sensor harness SYS board Scan motor Scan motor harness
Remedy: 1 Carriage lock Check if the carriage locking screw for packaging is attached. 2 2 Carriage home position sensor 1. Check if the harness is properly connected to the sensor. 2. Check if the harness is caught or open circuited. 3 3 SYS board 1. Check if the harness (CN121) of the carriage home position sensor is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24 V (CN125) on the SYS board is short circuited. 4. Check if 24 V is supplied to the SYS board (CN125). 4 4 Scan motor • Check if the belt tension is loosened (if the motor screw is loosened). • Check if the wire and the belt come off. • Check if the connector (CN124) is connected to the motor properly. • Check if the harness of the motor is caught or open circuited.
Code: C290
Description: The scanning system does not operate due to a blowout of the fuse in the scanning system.
Causes: SYS board Fuse (F203) Supply harness LVPS
Remedy: 1 Is 24V supplied to the SYS board? Yes Check the following because the signal for checking 24V on the SYS board is abnormal. 1. Check if the scanner CPU (IC26) is damaged or abnormal. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24V on the SYS board is short circuited. 4. Check if 24V is supplied to the SYS board (CN125). No 1. Check if the 24V supply harness is properly connected to the connector (CN125). 2. Check if 24V and SG on the SYS board are short circuited. 3. Check if the power supply is short circuited by pulling out the supply harness on the SYS board (CN125). 4. Check if the fuse on the LVPS (F203) is open circuited. 5. Check if there is no abnormality on the LVPS.
Code: C370
Description: Transfer belt unit abnormality
Causes: Drum TBU motor LGC board 1st transfer roller status detection sensor (S12) 1st transfer contact/release clutch (CLT3)
Remedy: Transfer belt unit Check if the transport belt unit is working normally. Drum TBU drive unit Connector check (CN368, J808, J809) Drum TBU motor Connector check Drum cleaner unit Check if the drum is overloaded. Transfer belt cleaning unit Check that there is no abnormality in the cleaning blade. Check if the waste toner auger is overloaded. LGC board Connector check (CN368) Transfer belt Check if it’s normal 1st transfer roller status detection sensor (S12) Sensor check 1st transfer contact/release clutch (CLT3) Clutch check
Causes: Auto toner sensor Harness LGC board Developer material High-voltage transformer
Remedy: 1 Developer unit • Check if the developer unit is installed properly. • Check that the developer unit and coupling on the equipment side are properly engaged. • Check that the mixer of the developer unit is rotated. • Check if the developer material is too light visually. • Check if the amount of the developer material is too large or too small. • Remove any toner or dust on the auto-toner sensor connector and the drawer connector of the process cover. • Remove any toner or dust on the EPU sensor connector and the drawer connector on the equipment side. 2 Auto toner sensor - Equipment Harness - LGC board • Check the connectors and harnesses between the auto toner sensor and LGC board (CN347). • Remove any foreign matter such as toner in the connector of the auto toner sensor.
Causes: Auto toner sensor Harness LGC board Developer material
Remedy: 1 Developer unit • Check if the developer unit is installed properly. • Check that the developer unit and coupling on the equipment side are properly engaged. • Check that the mixer of the developer unit is rotated. • Check if the amount of the developer material is too large or too small. • Remove any toner or dust on the auto-toner sensor connector and the drawer connector of the process cover. • Remove any toner or dust on the EPU sensor connector and the drawer connector on the equipment side. 2 Auto toner sensor Harness LGC board • Check the connectors and harnesses between the auto toner sensor and LGC board (CN347). • Check if there is any foreign matter such as toner in the connector of the auto toner sensor. Remove if there is and reconnect it.