Description: SRAM and NVRAM abnormality on the SYS board
Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) When the message “NVRAM/SRAM ERROR DOES IT INITIALIZE?” is displayed on the LCD, press the [INTERRUPT] or [INITIALIZE] button. (SRAM is cleared and NVRAM is initialized.) (3) Perform the panel calibration (08-692). Note: When the NVRAM is initialized, the scanner and image processing related adjustments are also initialized. Readjust them after the NVRAM initialization. (4) Turn the power OFF and then back ON. If the error is not recovered, replace the NVRAM on the SYS board.
Code: F100
Description: HDD format error: HDD cannot be initialized normally.
Remedy: (1) Check if the HDD is mounted. (2) Check if the specified HDD is mounted. (3) Check if the connector pins of the HDD are bent. (4) Check if the connectors CN112, CN113 on the SYS board is disconnected. (5) Replace the harness. (6) Format the HDD. (Key in "2" at 08-690.) (7) Replace the HDD. (8) Replace the SYS board.
Code: F101
Description: HDD unmounted: Connection of HDD cannot be detected.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Code: F102
Description: HDD start error: HDD cannot become ‘Ready’ state.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Code: F103
Description: HDD transfer time-out: Reading/writing cannot be performed in the specified period of time.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Code: F104
Description: HDD data error: Abnormality is detected in the data of HDD.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Code: F105
Description: HDD other error
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Code: F106
Description: Point and Print partition damage
Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.