Các lỗi thường gặp

Code :
  • Code: SC270
  • Description: Mirror motor upper/lower limit: Y (Yellow) The pulse rate of the mirror motor reaches the upper or lower limit. Note: SP2182 displays the pulse rate for each motor.
  • Remedy: • 3rd mirror motor is defective. • 3rd mirror motor connecter is not connected correctly.
  • Code: SC271
  • Description: Mirror motor upper/lower limit: M (Magenta) The pulse rate of the mirror motor reaches the upper or lower limit. Note: SP2182 displays the pulse rate for each motor.
  • Remedy: • 3rd mirror motor is defective. • 3rd mirror motor connecter is not connected correctly.
  • Code: SC272
  • Description: Mirror motor upper/lower limit: C (Cyan) The pulse rate of the mirror motor reaches the upper or lower limit. Note: SP2182 displays the pulse rate for each motor.
  • Remedy: • 3rd mirror motor is defective. • 3rd mirror motor connecter is not connected correctly.
  • Code: SC285
  • Description: MUSIC error. An error with the MUSIC occurs four times since the last time the main power was turned ON.
  • Remedy: • ITB defective • MUSIC sensors are dirty • MUSIC sensors are defective
  • Code: SC300
  • Description: AC charge output error 1: K An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
  • Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
  • Code: SC301
  • Description: AC charge output error 2: M An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
  • Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
  • Code: SC302
  • Description: AC charge output error 3: C An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
  • Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
  • Code: SC303
  • Description: AC charge output error 4: Y An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
  • Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.