Description: Mirror motor upper/lower limit: Y (Yellow) The pulse rate of the mirror motor reaches the upper or lower limit. Note: SP2182 displays the pulse rate for each motor.
Remedy: • 3rd mirror motor is defective. • 3rd mirror motor connecter is not connected correctly.
Description: Mirror motor upper/lower limit: M (Magenta) The pulse rate of the mirror motor reaches the upper or lower limit. Note: SP2182 displays the pulse rate for each motor.
Remedy: • 3rd mirror motor is defective. • 3rd mirror motor connecter is not connected correctly.
Description: Mirror motor upper/lower limit: C (Cyan) The pulse rate of the mirror motor reaches the upper or lower limit. Note: SP2182 displays the pulse rate for each motor.
Remedy: • 3rd mirror motor is defective. • 3rd mirror motor connecter is not connected correctly.
Description: AC charge output error 1: K An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
Description: AC charge output error 2: M An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
Description: AC charge output error 3: C An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
Description: AC charge output error 4: Y An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BICU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Remedy: • High voltage power supply • BICU defective • OPC unit defective 1. Disconnect the high voltage cable from Terminal C of the multiple highvoltage supply board. 2. Attach a voltmeter to the terminal. 3. If there is no output from the terminal, replace the high voltage power supply. -or- If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the highvoltage harness for defects and replace it if necessary. 4. Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. 5. If there is no charge PWM signal, replace the harness and/or BICU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.