Description: No lock detected at motor start for motor ID. Motor is type 1.
Causes: • Check for paper jams • Gear binds • Defective motor • Check motor cable and connections
Remedy:
Description: No lock detected at normal motor start. Motor is type 0.
Causes: • Check for paper jams • Gear binds • Defective motor • Check motor cable and connections
Remedy:
Description: No lock detected at normal motor start. Motor is type 1.
Causes: • Check for paper jams • Gear binds • Defective motor. • Defective motor cable • Cable connections
Remedy:
Description: Stall detected during speed control. Motor is type 0.
Causes: • Defective cable • Check cable connections • Defective motor • Paper jams
Remedy:
Description: Stall detected during speed control. Motor is type 1.
Causes: • Defective cable • Check cable connections • Defective motor • Paper jams
Remedy:
Description: Overspeed detected during speed control. Motor is type 0.
Causes: • Faulty motor sensor • Faulty system board
Remedy:
Description: Overspeed detected during speed control. Motor is type 1.
Causes: • Faulty motor sensor • Faulty system board
Remedy:
Description: Overspeed detected during position control. Motor is type 0.
Causes: • Faulty motor sensor • Faulty system board
Remedy: