Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Xerox Phaser 7800 — Trang 32/58

Code: 347.213

Description: Finisher Kind Mismatch. A Finisher other than the specified one is connected.
Remedy: 1. Turn the power Off and On. 2. Turn the power Off and connect a Finisher that is supported by this machine.

Code: 347.216

Description: Finisher Communication Fault. Communication failure between the Finisher and the IOT was detected.
Remedy: 1. Turn the power Off and On. 2. Turn the power Off and check the connection between the MD PWB P/J590/ and the Finisher PWB P/J591 for open circuit, short circuit, and poor contact. Also, check the power supply at the Finisher. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB

Code: 347.320

Description: ALL Destination Tray Broken. All Trays connected to the IOT have become unusable.
Remedy: Enter dc122 Fault History. Go to the RAP of the affected Output Tray.

Code: 361.350

Description: LPH Power On Fault Y. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (Y) P/J553 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (Y) P/J565 and the LPH (Y) P/J573 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J557 pins-28/27 and LPH Rear PWB (Y) P/J561 pins-1/2) • The Flat Cable between the LPH H PWB (Y) P/J569 and the LPH (Y) P/J577 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J581 between the LPH Rear PWB (Y) and the LPH H PWB (Y) for damage and foreign substances • The LPH Unit (Y) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MD PWB • MCU PWB

Code: 361.351

Description: LPH Power On Fault M. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (M) P/J552 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (M) P/J564 and the LPH (M) P/J572 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J556 and the LPH Rear PWB (M) P/J560 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J556 pins-28/27 and LPH Rear PWB (M) P/J560 pins-1/2) • The Flat Cable between the LPH H PWB (M) P/J568 and the LPH (M) P/J576 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J580 between the LPH Rear PWB (M) and the LPH H PWB (M) for damage and foreign substances • The LPH Unit (M) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (M) • LPH Cable Assembly • LPH Rear PWB (M) • MD PWB • MCU PWB

Code: 361.352

Description: LPH Power On Fault C. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (C) P/J551 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (C) P/J563 and the LPH (C) P/J571 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J555 and the LPH Rear PWB (C) P/J559 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J555 pins-28/27 and LPH Rear PWB (C) P/J559 pins-1/2) • The Flat Cable between the LPH H PWB (C) P/J567 and the LPH (C) P/J575 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J579 between the LPH Rear PWB (C) and the LPH H PWB (C) for damage and foreign substances • The LPH Unit (C) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (C) • LPH Cable Assembly • LPH Rear PWB (C) • MD PWB • MCU PWB

Code: 361.353

Description: LPH Power On Fault K. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (K) P/J550 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (K) P/J562 and the LPH (K) P/J570 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J554 and the LPH Rear PWB (K) P/J558 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J554 pins-28/27 and LPH Rear PWB (K) P/J558 pins-1/2) • The Flat Cable between the LPH H PWB (K) P/J566 and the LPH (K) P/J574 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J578 between the LPH Rear PWB (K) and the LPH H PWB (K) for damage and foreign substances • The LPH Unit (K) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (K) • LPH Cable Assembly • LPH Rear PWB (K) • MD PWB • MCU PWB

Code: 361.354

Description: LPH Download Data Fault Y. DELSOL register data error during the LPH batch download complete verification, download error, or connector error.
Remedy: Check the following: • The Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (Y) P/J569 and the LPH (Y) P/J577 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J581 between the LPH Rear PWB (Y) and the LPH H PWB (Y) for damage and foreign substances • The LPH Unit (Y) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MCU PWB
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie