Các lỗi thường gặp

Code :
  • Code: 347.213
  • Description: Finisher Kind Mismatch. A Finisher other than the specified one is connected.
  • Remedy: 1. Turn the power Off and On. 2. Turn the power Off and connect a Finisher that is supported by this machine.
  • Code: 347.216
  • Description: Finisher Communication Fault. Communication failure between the Finisher and the IOT was detected.
  • Remedy: 1. Turn the power Off and On. 2. Turn the power Off and check the connection between the MD PWB P/J590/ and the Finisher PWB P/J591 for open circuit, short circuit, and poor contact. Also, check the power supply at the Finisher. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB
  • Code: 347.320
  • Description: ALL Destination Tray Broken. All Trays connected to the IOT have become unusable.
  • Remedy: Enter dc122 Fault History. Go to the RAP of the affected Output Tray.
  • Code: 361.350
  • Description: LPH Power On Fault Y. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
  • Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (Y) P/J553 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (Y) P/J565 and the LPH (Y) P/J573 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J557 pins-28/27 and LPH Rear PWB (Y) P/J561 pins-1/2) • The Flat Cable between the LPH H PWB (Y) P/J569 and the LPH (Y) P/J577 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J581 between the LPH Rear PWB (Y) and the LPH H PWB (Y) for damage and foreign substances • The LPH Unit (Y) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MD PWB • MCU PWB
  • Code: 361.351
  • Description: LPH Power On Fault M. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
  • Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (M) P/J552 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (M) P/J564 and the LPH (M) P/J572 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J556 and the LPH Rear PWB (M) P/J560 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J556 pins-28/27 and LPH Rear PWB (M) P/J560 pins-1/2) • The Flat Cable between the LPH H PWB (M) P/J568 and the LPH (M) P/J576 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J580 between the LPH Rear PWB (M) and the LPH H PWB (M) for damage and foreign substances • The LPH Unit (M) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (M) • LPH Cable Assembly • LPH Rear PWB (M) • MD PWB • MCU PWB
  • Code: 361.352
  • Description: LPH Power On Fault C. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
  • Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (C) P/J551 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (C) P/J563 and the LPH (C) P/J571 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J555 and the LPH Rear PWB (C) P/J559 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J555 pins-28/27 and LPH Rear PWB (C) P/J559 pins-1/2) • The Flat Cable between the LPH H PWB (C) P/J567 and the LPH (C) P/J575 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J579 between the LPH Rear PWB (C) and the LPH H PWB (C) for damage and foreign substances • The LPH Unit (C) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (C) • LPH Cable Assembly • LPH Rear PWB (C) • MD PWB • MCU PWB
  • Code: 361.353
  • Description: LPH Power On Fault K. Power source system error during LPH batch download complete verification or poor connection of Flat Cable.
  • Remedy: Check the following: • The connection between the MD PWB P/J532 and the LPH Rear PWB (K) P/J550 for open circuit, short circuit, and poor contact • The connection between the LPH H PWB (K) P/J562 and the LPH (K) P/J570 for open circuit, short circuit, and poor contact (connection within the LPH Unit) • The Flat Cable between the MCU PWB P/J554 and the LPH Rear PWB (K) P/J558 for open circuits, short circuits, and poor contacts (especially for short circuits between MCU PWB P/J554 pins-28/27 and LPH Rear PWB (K) P/J558 pins-1/2) • The Flat Cable between the LPH H PWB (K) P/J566 and the LPH (K) P/J574 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J578 between the LPH Rear PWB (K) and the LPH H PWB (K) for damage and foreign substances • The LPH Unit (K) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (K) • LPH Cable Assembly • LPH Rear PWB (K) • MD PWB • MCU PWB
  • Code: 361.354
  • Description: LPH Download Data Fault Y. DELSOL register data error during the LPH batch download complete verification, download error, or connector error.
  • Remedy: Check the following: • The Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (Y) P/J569 and the LPH (Y) P/J577 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J581 between the LPH Rear PWB (Y) and the LPH H PWB (Y) for damage and foreign substances • The LPH Unit (Y) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MCU PWB