Các lỗi thường gặp

Code :
  • Code: 361.371
  • Description: LPH Act Fault M. Communication error between MCU and LPH Unit (M) (error in the communication IC or cable).
  • Remedy: Check the timing at when this Fail occurs. Does this Fail occur right after the power is turned On? Y↓ N→If the Fail occurs when the Drum is rotating, it is very likely due to the noise caused by high voltage leak. Check the Drum (Y, M, C, K) for improper installation Check the following: • The Flat Cable between the MCU PWB P/J556 and the LPH Rear PWB (M) P/J560 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (M) P/J568 and the LPH (M) P/J576 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J580 between the LPH Rear PWB (M) and the LPH H PWB (M) for damage and foreign substances • The LPH Unit (M) for improper installation • The Drum/Dev Drive Motor (Y, M, C) for improper installation (affected by the noises caused by improper installation) If no problems are found, replace the following parts in sequence: • LPH Unit (M) • LPH Cable Assembly • LPH Rear PWB (M) • MCU PWB
  • Code: 361.372
  • Description: LPH Act Fault C. Communication error between MCU and LPH Unit (C) (error in the communication IC or cable).
  • Remedy: Check the timing at when this Fail occurs. Does this Fail occur right after the power is turned On? Y↓ N→If the Fail occurs when the Drum is rotating, it is very likely due to the noise caused by high voltage leak. Check the Drum (Y, M, C, K) for improper installation Check the following: • The Flat Cable between the MCU PWB P/J555 and the LPH Rear PWB (C) P/J559 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (C) P/J567 and the LPH (C) P/J575 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J579 between the LPH Rear PWB (C) and the LPH H PWB (C) for damage and foreign substances • The LPH Unit (C) for improper installation • The Drum/Dev Drive Motor (Y, M, C) for improper installation (affected by the noises caused by improper installation) If no problems are found, replace the following parts in sequence: • LPH Unit (C) • LPH Cable Assembly • LPH Rear PWB (C) • MCU PWB
  • Code: 361.373
  • Description: LPH Act Fault K. Communication error between MCU and LPH Unit (K) (error in the communication IC or cable).
  • Remedy: Check the timing at when this Fail occurs. Does this Fail occur right after the power is turned On? Y↓ N→If the Fail occurs when the Drum is rotating, it is very likely due to the noise caused by high voltage leak. Check the Drum (Y, M, C, K) for improper installation Check the following: • The Flat Cable between the MCU PWB P/J554 and the LPH Rear PWB (K) P/J558 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (K) P/J566 and the LPH (K) P/J574 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J578 between the LPH Rear PWB (K) and the LPH H PWB (K) for damage and foreign substances • The LPH Unit (K) for improper installation • The Drum/Dev Drive Motor (Y, M, C) for improper installation (affected by the noises caused by improper installation) If no problems are found, replace the following parts in sequence: • LPH Unit (K) • LPH Cable Assembly • LPH Rear PWB (K) • MCU PWB
  • Code: 361.374
  • Description: LPH Chip Fault Y. Open circuit detected in LPH Unit (Y) (open circuit between DELSOL and SLED).
  • Remedy: Enter dc122 Fault History. Check whether any Fail related to connection failure of the Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 has occurred. Has any Chain No. 361 Fail (other than LPH Chip Fail) occurred? Y↓ N→Replace the LPH Unit (Y). Go to the appropriate RAP
  • Code: 361.375
  • Description: LPH Chip Fault M. Open circuit detected in LPH Unit (M) (open circuit between DELSOL and SLED).
  • Remedy: Enter dc122 Fault History. Check whether any Fail related to connection failure of the Flat Cable between the MCU PWB P/J556 and the LPH Rear PWB (M) P/J560 has occurred. Has any Chain No. 361 Fail (other than LPH Chip Fail) occurred? Y↓ N→Replace the LPH Unit (M). Go to the appropriate RAP
  • Code: 361.376
  • Description: LPH Chip Fault C. Open circuit detected in LPH Unit (C) (open circuit between DELSOL and SLED).
  • Remedy: Enter dc122 Fault History. Check whether any Fail related to connection failure of the Flat Cable between the MCU PWB P/J555 and the LPH Rear PWB (C) P/J559 has occurred. Has any Chain No. 361 Fail (other than LPH Chip Fail) occurred? Y↓ N→Replace the LPH Unit (C). Go to the appropriate RAP.
  • Code: 361.377
  • Description: LPH Chip Fault K. Open circuit detected in LPH Unit (K) (open circuit between DELSOL and SLED).
  • Remedy: Enter dc122 Fault Historyy. Check whether any Fail related to connection failure of the Flat Cable between the MCU PWB P/J554 and the LPH Rear PWB (K) P/J558 has occurred. Has any Chain No. 361 Fail (other than LPH Chip Fail) occurred? Y↓ N→Replace the LPH Unit (K). Go to the appropriate RAP.
  • Code: 361.378
  • Description: LPH Ltrg Fault Y. The Ltrg signal (image synchronization signal) failure was detected.
  • Remedy: Check the following: • The Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (Y) P/J569 and the LPH (Y) P/J577 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J581 between the LPH Rear PWB (Y) and the LPH H PWB (Y) for damage and foreign substances • The LPH Unit (Y) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MCU PWB