Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Xerox Phaser 7800 — Trang 33/58

Code: 361.355

Description: LPH Download Data Fault M. DELSOL register data error during the LPH batch download complete verification, download error, or connector error.
Remedy: Check the following: • The Flat Cable between the MCU PWB P/J556 and the LPH Rear PWB (M) P/J560 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (M) P/J568 and the LPH (M) P/J576 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J580 between the LPH Rear PWB (M) and the LPH H PWB (M) for damage and foreign substances • The LPH Unit (M) for improper installation If no problems are found, replace the following parts in sequence: • LPH Unit (M) • LPH Cable Assembly • LPH Rear PWB (M) • MCU PWB

Code: 361.356

Description: LPH Download Data Fault C. DELSOL register data error during the LPH batch download complete verification, download error, or connector error.
Remedy: • The Flat Cable between the MCU PWB P/J555 and the LPH Rear PWB (C) P/J559 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (C) P/J567 and the LPH (C) P/J575 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J579 between the LPH Rear PWB (C) and the LPH H PWB (C) for damage and foreign substances • The LPH Unit (C) for improper installation If no problems are found, replace the following parts in sequence: • Use Software Versions (dc108 Software Versions) to verify the most current software is installed. – If a software upgrade is necessary go to GP 21. • LPH Unit (C) • LPH Cable Assembly • LPH Rear PWB (C) • MCU PWB

Code: 361.357

Description: LPH Download Data Fault K. DELSOL register data error during the LPH batch download complete verification, download error, or connector error.
Remedy: Check the following: • The Flat Cable between the MCU PWB P/J554 and the LPH Rear PWB (K) P/J558 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (K) P/J566 and the LPH (K) P/J574 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J578 between the LPH Rear PWB (K) and the LPH H PWB (K) for damage and foreign substances • The LPH Unit (K) for improper installation If no problems are found, replace the following parts in sequence: • Use Software Versions (dc108 Software Versions) to verify the most current software is installed. – If a software upgrade is necessary go to GP 21. • LPH Unit (K) • LPH Cable Assembly • LPH Rear PWB (K) • MCU PWB

Code: 361.358

Description: LPH Mismatch Fault Y. The model number of the LPH Unit (Y) does not match.
Remedy: Check the following: • Check that the values in dc131 NVM Read/Write [749-157] (LPH Specific Code 4Y) do not contain corruption, etc. • Use Software Versions (dc108 Software Versions) to verify the most current software is installed. – If a software upgrade is necessary go to GP 21. If no problems are found, replace the LPH Unit (Y).

Code: 361.359

Description: LPH Mismatch Fault M. The model number of the LPH Unit (M) does not match.
Remedy: Check the following: • Check that the values in dc108 Software Versions [749-158] (LPH Specific Code 4M) do not contain corruption, etc. • Use Software Versions (dc108 Software Versions) to verify the most current software is installed. – If a software upgrade is necessary go to GP 21. If no problems are found, replace the LPH Unit (M).

Code: 361.360

Description: LPH Mismatch Fault C. The model number of the LPH Unit (C) does not match.
Remedy: Check the following: • Check that the values in dc131 NVM Read/Write [749-159] (LPH Specific Code 4C) do not contain corruption, etc. • Use Software Versions (dc108 Software Versions) to verify the most current software is installed. – If a software upgrade is necessary go to GP 21. If no problems are found, replace the LPH Unit (C).

Code: 361.361

Description: LPH Mismatch Fault K. The model number of the LPH Unit (K) does not match.
Remedy: Check the following: • Check that the values in dc131 NVM Read/Write [749-160] (LPH Specific Code 4K) do not contain corruption, etc. • Use Software Versions (dc108 Software Versions) to verify the most current software is installed. – If a software upgrade is necessary go to GP 21. If no problems are found, replace the LPH Unit (K).

Code: 361.362

Description: LPH Read Fault Y. Communication error between MCU and LPH Unit (Y) (data read error from LPH)
Remedy: Check the following: • The Flat Cable between the MCU PWB P/J557 and the LPH Rear PWB (Y) P/J561 for open circuits, short circuits, and poor contacts • The Flat Cable between the LPH H PWB (Y) P/J569 and the LPH (Y) P/J577 for open circuits, short circuits, and poor contacts (connection within the LPH Unit) • The connector P/J581 between the LPH Rear PWB (Y) and the LPH H PWB (Y) for damage and foreign substances • The LPH Unit (Y) for improper installation • The Drum/Dev Drive Motor (Y, M, C) for improper installation (affected by the noises caused by improper installation) If no problems are found, replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MCU PWB