Code: 123-314

Description: UI Panel Communication Fail Communication failure between the ESS/MCU PWB and the UI Panel was detected.
Remedy: 1. Turn the power OFF and ON. 2. Turn OFF the power and check the Flat Cable between the UI PWB J740 and the ESS/ MCU PWB J422 for open circuits, short circuits, and poor contacts. 3. If no problem is found, replace the following parts in sequence: • UI PWB (PL 1.10) • ESS/MCU PWB (PL 18.3)

Code: 124-311

Description: Serial Number Fail The device was turned ON after it was installed with a new ESS/MCU PWB.
Remedy: 1. Remove the EEP ROM from the old ESS/MCU PWB, install the removed EEPROM to the new ESS/MCU PWB, and then turn ON the power. 2. Enter the Diag, input [621-400] in the Chain-Link, and set the value to '1'. 3. Press <Start>.

Code: 127-396

Description: E-mail Generate Fail Unable to generate the e-mail data for some reasons. Example: Failed to secure resources, error during input of header field, error during Base 64 conversion, etc.
Remedy: 1. Press [Stop] on the UI Panel. 2. Check and change the settings of the various items that are required for the operation. NOTE: When performing the operation again, the same Fault will occur if the user had proceeded without changing the settings. 3. Upgrade the Controller Firmware. ADJ 18.2.3

Code: 133-226

Description: Fax Country or Clock Not Set When activating Fax at power ON, the country code setting is 'Unknown' or the clock is not set.
Remedy: Set the country code to any option other than 'Unknown' and set the clock. Enter the Key Ope Tools Mode. • Country Code: Fax Setting > Region > Select Country > Apply Settings (Yes) > Auto- Reboot • Time: System Settings > Clock > >Date & Time > Select Time Zone > Date Settings > Time Settings > Save

Code: 134-210

Description: Fax Data Parameter Error Any one of Parameter Type Error, Parameter Data Error, or Parameter Length Error received from the Fax Board.
Remedy: 1. Turn the power OFF and ON. 2. Perform NVM Initialize in the CE Mode. For details on the NVM Initialize, refer to '6.5.2.4 NVM Initialize'. 3. If the problem persists, replace the Fax PWB (PL 18.5).

Code: 134-211

Description: Fax Board Failure Fax Board malfunction (Memory Error, Hardware Error) received from the Fax Board.
Remedy: 1. Turn the power OFF and ON. 2. Print out the Error Report and then replace the Fax PWB (PL 18.5). 3. Re-send the Fax or request for the customer to receive one.