Description: Lamp Illumination RAP The amount of light from Exposure Lamp is inadequate which gets incident on CCD at the start of scan or at the initialization of IIT after power on.
Remedy: Check the lamp, lens, mirror and the white correcting plate for abnormalities such as contamination and deterioration. Abnormality such as contamination or deterioration of the lamp, lens, mirror or the white correcting plate is found. Y↓N→Replace the lamp, lens, mirror or the white correcting plate. Execute Component Control [062-002 IIT Exposure Lamp]. The Exposure Lamp lights up. Y↓N→Check the connections of P/J703, P/J702 and P/J7231. P/J703, P/J702 and P/J7231 are connected correctly. Y↓N→Connect P/J703, P/J702 and P/J7231. Check the wire between J702 and J7231 for an open circuit or a short circuit. The wire between J702 and J7231 is conducting without an open circuit or a short circuit. Y↓N→Replace the Lamp Wire Harness (PL 11.6). Measure the voltage between the IIT/IPS PWB (PL 13.3) P7231-1 (+) and GND (-), and between P7231-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Exposure Lamp (PL 11.6) If the problem persists, replace the Lamp Ballast PWB (PL 11.6) If the problem persists, replace the IIT/IPS PWB (PL 13.3). Check the connections of P/J700 and P/J7101. P/J700 and P/J7101 are connected correctly. Y↓N→Connect P/J700 and P/J7101. Replace the Lens Kit Assembly (PL 11.4) If the problem persists, replace the IIT/IPS PWB (PL 11.3).
Code: 062-380
Description: Platen AGC CH1 RAP At the adjustment of CCD output after power on, CCD does not make a correct output which it should when it receives a specified amount of light.
Remedy: Check the lamp, lens, mirror and the white correcting plate for abnormalities such as contamination and deterioration. Abnormality such as contamination or deterioration of the lamp, lens, mirror or the white correcting plate is found. Y↓N→Replace the lamp, lens, mirror or the white correcting plate. Execute Component Control[062-002 IIT Exposure Lamp]. The Exposure Lamp lights up. Y↓N→Check the connections of P/J703, P/J702 and P/J7231. P/J703, P/J702 and P/J7231 are connected correctly. Y↓N→Connect P/J703, P/J702 and P/J7231. Check the wire between J702 and J7231 for an open circuit or a short circuit. The wire between J702 and J7231 is conducting without an open circuit or a short circuit. Y↓N→Replace the Lamp Wire Harness (PL 11.6). Measure the voltage between the IIT/IPS PWB (PL 13.3) P723-1 (+) and GND (-), and between P723-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Exposure Lamp (PL 11.6) If the problem persists, replace the Lamp Ballast PWB (PL 11.6) If the problem persists, replace the IIT/IPS PWB (PL 11.3). Check the connections of P/J700 and P/J7101. P/J700 and P/J7101 are connected correctly. Y↓N→Connect P/J700 and P/J7101. Replace the Lens Kit Assembly (PL 11.3) If the problem persists, replace the IIT/IPS PWB (PL 11.3).
Code: 062-386
Description: Platen AOC CH1 RAP At the adjustment of CCD output after power on, CCD does not make a correct output which it should when no light is incident on it.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures Replace the Lens Kit Assembly (PL 11.3) If the problem persists, replace the IIT/IPS PWB (PL 11.3).
Code: 062-389
Description: Carriage Over Run RAP The carriage scanned beyond safe limits.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures Replace the IIT/IPS PWB (PL 11.3).
Code: 062-392
Description: IIT/IPS PWB Memory Failure-1 RAP • The IIT/IPS PWB RAM failed during the Read/Write operation. • The Shading Memory failed during the Read/Write operation. • The Gap Memory failed during the Read/Write operation. • The ASIC (Application Specific Integrated Circuit) failed.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures Replace the IIT/IPS PWB (PL 11.3).
Code: 062-393
Description: IIT/IPS PWB RAM RAP An internal processing error occurred in the IIT/IPS PWB.
Remedy: Check the connection of each IIT/IPS PWB (PL 13.3) connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. If the problem persists replace the IIT/IPS PWB (PL 11.3). If the problem persists, replace the Lens Kit Assembly (PL 11.3).
Code: 062-500
Description: IISS ROM RAP IISS ROM Failure.
Remedy: Check the connections on the IIT/IPS PWS (PL 11.3). Check that the prom on the IIT/IPS PWB is seated properly. If the above checks are OK, replace the IIT/IPS PWB (PL 11.3). Perform Max Setup if the IIT/IPS PWB was replaced. Perform DADF Registration Setup (ADJ 15.1.4).
Code: 062-790
Description: Prohibited Document Detection RAP Control logic detects a prohibited document.
Remedy: Ask the customer to verify that the document is not a prohibited document. Refer to Prohibited Documents in SGS 12. If the document is not prohibited, replace the IIT/IPS PWB (PL 11.3).