Description: IIT/IPS PWB EEPROM RAP The IPS EEPROM failed during the Read/Write operation.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures Replace the IIT/IPS PWB (PL 11.3).
Description: IIT/IPS PWB DADF PWB Communication RAP Transmission error occurred between the IIT/IPS PWB and the DADF PWB.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each DADF PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between P/J751 and P750, and between P/J752 and P750 for an open circuit or a short circuit. The wires between P/J751 and P750, and between P/J752 and P750 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the IIT/IPS PWB (PL 11.3). If the problem persists, replace the DADF PWB (PL 15.3).
Description: Platen Interlock Open RAP The Platen Interlock is open
Remedy: Check opening/closing of the Platen Cover. The Platen Cover can be opened/closed. Y↓N→Reinstall the Platen Cover correctly. Check the installation of the Platen Angle Sensor. The Platen Angle Sensor is installed correctly. Y↓N→Install the Platen Angle Sensor correctly. Execute Component Control [062-301 Platen Angle Sensor]. Open and close the Platen Cover. The display changes. Y↓N→Check the connections of P/J725 and P/J722. P/J725 and P/J722 are connected correctly. Y↓N→Connect P/J725 and P/J722. Check the wire between J725 and J722 for an open circuit or a short circuit. The wire between J725 and J722 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the IIT/IPS PWB P722-B7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Measure the voltage between the IIT/IPS PWB P722-B9 (+) and GND (-). Actuate the Platen Angle Sensor with paper. The voltage changes. Y↓N→Replace the Platen Angle Sensor (PL 11.4). Replace the Platen Angle Sensor (PL 13.4). Replace the IIT/IPS PWB (PL 11.3).
Description: IIT/IPS PWB Controller Communication RAP Transmission error occurred between the IIT/IPS PWB and the ESS PWB.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each ESS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between P/J720, P/J7193 and P/J320 for an open circuit or a short circuit. The wire between J720, 719, and J320 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the IIT/IPS PWB (PL 11.3). If the problem persists, replace the ESS PWB (PL 9.2).
Description: IIT/IPS Subsystem RAP The IPS EEPROM failed during a read/write operation.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures. Replace the IIT/IPS PWB (PL 11.3).
Remedy: Remove the Platen Glass. Execute Component Control [062-017 CCD Fan]. The CCD Fan operates. Y↓N→Replace the CCD Fan (PL 6.4). Check CCD Fan connections and wiring for damage.
Description: Carriage Position RAP • An error occurred while counting the pulses of the Carriage Motor. • After the Carriage Motor turned On, the IIT Registration Sensor did not turn On within the specified time.
Remedy: Check the Carriage Rail for dirt or contamination or distortion. Dirt or contamination or distortion is found in the Carriage Rail. Y↓N→Clean the rails or correct the distortion (PL 11.4). Execute Component Control [062-212 IIT Registration Sensor]. Actuate the IIT Registration Sensor with paper. The display changes. Y↓N→Check the connections of P/J728 and P/J7193. P/J728 and P/J7193 are connected correctly. Y↓N→Connect P/J728 and P/J7193. Check the wire between J728 and J7193 for an open circuit or a short circuit. The wire between J728 and J7193 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the IIT/IPS PWB P7193-B10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Measure the voltage between the IIT/IPS PWB P7193-B12 (+) and GND (-). Actuate the IIT Registration Sensor (PL 11.4) with paper. The voltage changes. Y↓N→Replace the IIT Registration Sensor (PL 11.4). Replace the IIT/IPS PWB (PL 11.3). Alternately execute Component Control[062-005 Carriage Motor SCAN ON] and Component Control[062-006 Carriage Motor RETURN ON]. The Carriage Motor starts up. Y↓N→Check the connection P/J721. P/J721 is connected correctly. Y↓N→Connect P/J721. Check the wires on J721 for an open circuit or a short circuit. The wires on J721 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Carriage Motor (PL 11.5). The resistance between J721- 1/2 and J721-3/4/5/6 is approx. 1Ohm. Y↓N→Replace the Carriage Motor (PL 11.5). Measure the voltage between the IIT/IPS PWB (PL 11.3) P721-1/2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Carriage Motor (PL 11.5) If the problem persists, replace the IIT/IPS PWB (PL 11.3). Replace the IIT/IPS PWB (PL 11.3).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.