Description: Toner CRUM Data Broken RAP The system detected that the data written to the Toner CRUM and the data read from the Toner CRUM do not match. NOTE: The WC 5325/5330/5335 is shipped with “Worldwide Neutral” Toner Cartridges. When the cartridges shipped with the machine are installed, the machine is set to Worldwide Neutral configuration. When the first toner cartridge is replaced in the WC 5325/5330/5335, the Geographic Differentiation Code and Toner Cartridge Type in NVM are automatically changed to the same settings as the replacement cartridge. Once these NVM are set, the WC 5325/5330/5335 toner configuration can only be changed with a CRUM conversion. One or more Toner Cartridges are of the wrong type (i.e., a “Sold” cartridge installed in a “metered” configured machine.
Remedy: An Error Message appears on the UI - Reinsert an improperly seated consumable or replace any consumables with Error. Press Machine Status button and select Supplies tab for details. Remove and reinstall the Toner Cartridge and check for improper installation. The problem continues Y↓N→End Check the NVM locations in Table 767-094 Geographic Setting 3 = North America/Europe 12 = DMO 15 = Worldwide 767-104 Contract Type 2 = Sold 3 = Metered 31 = Neutral The NVM values match the expected customer configuration. Y↓N→Determine correct Contract Type from customer. Contact Technical Support Center or your NTS for the CRUM conversion procedure. 1. Polish the connection terminals between the Toner Cartridge CRUM PWB and the Toner CRUM PWB with a dry cloth. (When cleaning, do not use Drum cleaner, etc.) 2. Check the following: • The connection between the MCU PWB P/J404 and the Toner CRUM PWB P/J102 for open circuit, short circuit, and poor contact • The connection terminals between the Toner Cartridge CRUM PWB and the Toner CRUM PWB for damage and foreign substances • The Toner Cartridge for improper installation If no problems are found, replace the following parts in sequence: • Toner Cartridge (K) (PL 8.1) • Toner CRUM PWB (PL 8.2) • MCU PWB (PL 18.2)
Code: 093-926
Description: Toner CRUM Data Mismatch Fail RAP Incorrect authentication area data was detected in the Toner CRUM. This fault is displayed if the wrong type of Toner cartridge is installed. NOTE: The WC 5325/5330/5335 is shipped with “Worldwide Neutral” Toner Cartridges. When the cartridges shipped with the machine are installed, the machine is set to Worldwide Neutral configuration. When the first toner cartridge is replaced in the WC 5325/5330/5335, the Geographic Differentiation Code and Toner Cartridge Type in NVM are automatically changed to the same settings as the replacement cartridge. Once these NVM are set, the WC 5325/5330/5335 toner configuration can only be changed with a CRUM conversion. One or more Toner Cartridges are of the wrong type (i.e., a “Sold” cartridge installed in a “metered” configured machine.
Remedy: An Error Message appears on the UI - Reinsert an improperly seated consumable or replace any consumable with an Error. Press Machine Status button and select Supplies tab for details. Remove and reinstall the Toner Cartridge and check for improper installation. The problem continues Y↓N→End Check the NVM locations in Table 767-094 Geographic Setting 3 = North America/Europe 12 = DMO 15 = Worldwide 767-104 Contract Type 2 = Sold 3 = Metered 31 = Neutral The NVM values match the expected customer configuration. Y↓N→Determine correct Contract Type from customer. Contact Technical Support Center or your NTS for the CRUM conversion procedure. 1. Polish the connection terminals between the Toner Cartridge CRUM PWB and the Toner CRUM PWB with a dry cloth. (When cleaning, do not use Drum cleaner, etc.) 2. Check the following: • The connection between the MCU PWB P/J404 and the Toner CRUM PWB P/J102 for open circuit, short circuit, and poor contact • The connection terminals between the Toner Cartridge CRUM PWB and the Toner CRUM PWB for damage and foreign substances • The Toner Cartridge for improper installation If no problems are found, replace the following parts in sequence: • Toner Cartridge (PL 8.1) • Toner CRUM PWB (PL 8.2) • MCU PWB (PL 18.2)
Code: 093-956
Description: Dev Install Mode Fail RAP In the Install Developer mode after the installation of the Xerographic Cartridge, no picture is painted on the patch. (The seal is left unremoved.)
Remedy: Peel off the developer seal from the Xerographic Cartridge.
Code: 093-959
Description: Dev Install Times Over Fail RAP The number of Developer installation mode executions has exceeded the upper limit.
Remedy: Replace the Xerographic Cartridge
Code: 094-315
Description: BTR Illegal output BTR output is implemented while Drum Motor is stopped
Remedy: If the problem is still present, reload system software (GP 16) If the problem persists, replace the MCU PWB (PL 18.2) .