Description: Dispense Fail RAP Toner Cartridge becomes Empty despite less use of Toner amount.
Remedy: Check the following: • The connection between the MCU PWB P/J413 and the Xero/Developer Cartridge P/ J615 for open circuit, short circuit, and poor contact • The Toner Dispense Motor for revolution failure: Component Control [093-002] (PL 8.2) • The Toner Cartridge for internal toner blockage If no problems are found, replace the following parts in sequence: • Drum Cartridge (PL 8.1) • MCU PWB (PL 18.2)
Code: 092-656
Description: ATC Average Fail RAP The average measured value of ATC Sensor is out of the range of appropriate values. (This is a hidden failure. Data is only recorded in history.)
Remedy: Check the following: • The connection between the MCU PWB P/J413 and the Xero/Developer Cartridge P/ J615 for open circuit, short circuit, and poor contact • The Toner Dispense Motor for revolution failure: Component Control [093-002] (PL 8.2) • The Toner Cartridge for internal toner blockage If no problems are found, replace the following parts in sequence: • Drum Cartridge (PL 8.1) • MCU PWB (PL 18.2)
Code: 092-660
Description: ATC Amplitude Fail RAP The difference between the maximum and minimum values in the ATC Sensor measurement set is lower than the threshold value. (This is a hidden failure. Data is only recorded in history.)
Remedy: Check the following: • The connection between the MCU PWB P/J413 and the Xero/Developer Cartridge P/ J615 for open circuit, short circuit, and poor contact • The Toner Dispense Motor for revolution failure: Component Control [093-002] (PL 8.2) • The Toner Cartridge for internal toner blockage If no problems are found, replace the following parts in sequence: • Drum Cartridge (PL 8.1) • MCU PWB (PL 18.2)
Code: 093-400
Description: Toner Cartridge Near Empty RAP It was detected that the replacement timing for Toner Cartridge is closer than Pre Near.
Remedy: The Toner Cartridge needs to be replaced soon. Replace the Toner Cartridge as required.
Code: 093-406
Description: Toner Cartridge Pre Near Empty RAP It was detected that the Toner Cartridge needs to be replaced soon.
Remedy: The Toner Cartridge needs to be replaced soon. Replace the Toner Cartridge as required.
Code: 093-912
Description: Toner Cartridge Empty The Toner Cartridge Empty state was detected.
Remedy: Replace the Toner Cartridge.
Code: 093-916
Description: Toner CRUM Not In Position RAP The Toner CRUM is not in the proper position. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch. NOTE: The WC 5325/5330/5335 is shipped with “Worldwide Neutral” Toner Cartridge. When the cartridges shipped with the machine are installed, the machine is set to Worldwide Neutral configuration. When the first toner cartridge is replaced in the WC 5325/5330/5335, the Geographic Differentiation Code and Toner Cartridge Type in NVM are automatically changed to the same settings as the replacement cartridge. Once these NVM are set, the WC 5325/5330/5335 toner configuration can only be changed with a CRUM conversion. One or more Toner Cartridges are of the wrong type (i.e., a “Sold” cartridge installed in a “metered” configured machine.
Remedy: 1. Remove and reinstall the Toner Cartridge. 2. Polish the connection terminals between the Toner Cartridge CRUM PWB and the Toner CRUM PWB with a dry cloth. (When cleaning, do not use Drum cleaner, etc.) 3. Check the following: • The connection between the MCU PWB P/J404 and the Toner CRUM PWB P/J102 for open circuit, short circuit, and poor contact • The connection terminals between the Toner Cartridge CRUM PWB and the Toner CRUM PWB for damage and foreign substances • The Toner Cartridge for improper installation If no problems are found, replace the following parts in sequence: • Toner Cartridge (PL 8.1) • Toner CRUM PWB (PL 8.2) • MCU PWB (PL 18.2) • Go to the 093-926 Toner CRUM Data Mismatch Fail RAP.
Code: 093-924
Description: Toner K CRUM Communication Fail RAP Communication failure with Toner CRUM was detected. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch. NOTE: The WC 5325/5330/5335 is shipped with “Worldwide Neutral” Toner Cartridges. When the cartridges shipped with the machine are installed, the machine is set to Worldwide Neutral configuration. When the first toner cartridge is replaced in the WC 5325/5330/5335, the Geographic Differentiation Code and Toner Cartridge Type in NVM are automatically changed to the same settings as the replacement cartridge. Once these NVM are set, the WC 5325/5330/5335 toner configuration can only be changed with a CRUM conversion. One or more Toner Cartridges are of the wrong type (i.e., a “Sold” cartridge installed in a “metered” configured machine.
Remedy: 1. Turn the power OFF and ON. 2. Check the connection between the MCU PWB P/J404 and the Toner CRUM PWB P/ J102 for open circuit, short circuit, and poor contact. Also, remove and reinstall the Toner Cartridge and check for improper installation. If no problems are found, replace the following parts in sequence: • Toner Cartridge (PL 8.1) • Toner CRUM PWB (PL 8.2) • MCU PWB (PL 18.2) • Go to the 093-926 Toner CRUM Data Mismatch Fail RAP.