Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Xerox WorkCentre 5855 — Trang 9/28

Code: 311-130-00-110, 311-132-00-110

Description: Paper Exiting to Bin 0 RAP 311-130-00-110 The leading edge of the sheet is late to the top exit sensor. 311-132-100-10 The trailing edge of the sheet is late from the top exit sensor.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. Enter dC330 code 011-001 to run transport motor 2, MOT11-001. MOT11-001 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J309, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 2, PL 11.22 Item 5. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-002 to energize the diverter gate solenoid, SOL11-002. SOL11-002 energizes. Y↓N→Go to Flag 2. Check SOL11-002. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 12, How to Check a Solenoid. • P/J306, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Diverter gate solenoid, PL 11.22 Item 12. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-130, actuate the top exit sensor, Q11-130. The display changes. Y↓N→Go to Flag 1. Check Q11-130. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 11, How to Check a Sensor. • P/J313, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Top exit sensor, PL 11.22 Item 11. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-000 to energize the transport motor 1, MOT11-000. MOT11- 000 runs. Y↓N→Go to Flag 4. Check MOT11-000. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J305, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 1, PL 11.14 Item 2. • 2K LCSS PWB, PL 11.26 Item 1. Perform SCP 5 Final Actions.

Code: 311-130-00-120, 311-132-00-120

Description: Paper Exiting to Bin 0 RAP 311-130-00-120 The leading edge of the sheet is late to the top exit sensor. 311-132-00-120 The trailing edge of the sheet is late from the top exit sensor.
Remedy: NOTE: All 1K LCSS interlocks must be made to supply +24V to the motors. Enter dC330 code 011-001 transport motor 2, MOT11-001. MOT11-001 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J16, 1K LCSS PWB. • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 2, PL 11.120 Item 13. • 1K LCSS PWB, PL 11.124 Item 1. NOTE: The diverter gate solenoid remains energized for 5 seconds. Enter dC330 code 011-002 diverter gate solenoid, SOL11-002. SOL11-002 energizes. Y↓N→Go to Flag 2. Check SOL11-002. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 12, How to Check a Solenoid. • P/J13, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Diverter gate solenoid, PL 11.118 Item 12. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-130, top exit sensor, Q11-130. Actuate Q11-130. The display changes. Y↓N→Go to Flag 1. Check Q11-130. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 11, How to Check a Sensor. • P/J2, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Top exit sensor, PL 11.118 Item 11. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-000, transport motor 1, MOT11-000. MOT11-000 runs. Y↓N→Go to Flag 4. Check MOT11-000. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J17, 1K LCSS PWB. • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 1, PL 11.110 Item 2. • 1K LCSS PWB, PL 11.124 Item 1. Perform SCP 5 Final Actions.

Code: 311-130-00-150, 311-132-00-150

Description: LVF BM Paper Exiting to Bin 0 RAP 311-130-00-150 The leading edge of the sheet is late to the top exit sensor. 311-132-100-150 The trailing edge of the sheet is late from the top exit sensor.
Remedy: NOTE: All LVF BM interlocks must be made to supply +24V to the motors. Enter dC330, code 011-001 to run transport motor 2, MOT11-001. The motor runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • GP 10, How to Check a Motor. • P/J309, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Transport motor 2, PL 11.70 Item 5. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-002 to energize the diverter gate solenoid, S11-002. The diverter gate solenoid energizes. Y↓N→Go to Flag 2. Check SOL11-002. Refer to: • GP 12, How to Check a Solenoid. • P/J306, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Bin 0/bin 1 diverter gate solenoid, PL 11.70 Item 12. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-130, actuate the top exit sensor, Q11-130. The display changes. Y↓N→Go to Flag 1. Check Q11-130. Refer to: • GP 11, How to Check a Sensor. • P/J314, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Top exit sensor, PL 11.70 Item 11. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-000 to energize the transport motor 1, MOT11-000. The motor energizes. Y↓N→Go to Flag 4. Check MOT11-000. Refer to: • GP 10, How to Check a Motor. • P/J305, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Transport motor 1, PL 11.62 Item 2. • LVF PWB, PL 11.90 Item 8. Perform SCP 5 Final Actions.

Code: 311-130-00-171, 311-132-00-171

Description: HVF Top Exit Sensor RAP 311-130-00-171 The paper leading edge is late arriving at the top exit sensor. 311-132-00-171 The paper trailing edge is late leaving the top exit sensor.
Remedy: Enter dC330 code 011-130. Manually operate the top exit sensor, Q11-130. The display changes. Y↓N→Go to Flag 1. Check Q11-130. Refer to: • GP 11 How to Check a Sensor. • P/J101, HVF Control PWB • 311A-171 HVF Power Distribution RAP Install new components as necessary: • Top exit sensor, PL 11.156 Item 3. • HVF control PWB, PL 11.157 Item 2 Enter dC330 code 011-002. Energize the exit diverter solenoid, SOL 11-002. SOL11-002 energizes. Y↓N→Go to Flag 2. Check SOL 11-002. Refer to: • GP 12, How to Check a Solenoid or Clutch. • P/J102, HVF Control PWB • 311A-171 HVF Power Distribution RAP. Install new components as necessary: • Exit diverter solenoid, PL 11.150 Item 4. • HVF control PWB, PL 11.157 Item 2 Enter dC330 code 011-001 to run the transport motor 2, MOT11-001. MOT11-001 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • GP 10 How to Check a Motor. • P/J102, HVF Control PWB • 311A-171 HVF Power Distribution RAP Install new components as necessary: • Transport motor 2, PL 11.150 Item 1. • HVF control PWB, PL 11.157 Item 2. Check the drive belt on the motor. The drive belt is good. Y↓N→Install a new drive belt, PL 11.150 Item 7. The fault may be intermittent, check for damaged wiring or bad connectors. If necessary install new components: • Top exit sensor, PL 11.156 Item 3. • Exit diverter solenoid, PL 11.150 Item 4. • Diverter gate, PL 11.153 Item 9. • Transport motor 2, PL 11.150 Item 1. • HVF control PWB, PL 11.157 Item 2.

Code: 311-140-00-110, 311-142-00-110

Description: Sheet Late to Bin 1 RAP 311-140-00-110 The leading edge of the sheet is late to the 2nd to top exit sensor, Q11-140. 311-142-00-110 The trailing edge of the sheet is late to the 2nd to top exit sensor, Q11-140.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors.. Enter dC330 code 011-001 to energize the transport motor 2, MOT11-001. MOT11- 110 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 10, How to check a motor. • P/J309, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 2, PL 11.22 Item 5. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-002 to energize the diverter solenoid, SOL11-002. The diverter solenoid energizes. Y↓N→Go to Flag 4. Check SOL11-002. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 12, How to Check a Solenoid or Clutch. • P/J306, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Diverter gate solenoid, PL 11.22 Item 12. • 2K LCSS PWB, PL 11.26 Item 1.. Enter dC330 code 011-140, actuate the 2nd to top exit sensor, Q11-140. The display changes. Y↓N→Go to Flag 1. Check Q11-140. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 11, How to Check a sensor. • P/J313, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • 2nd to top exit sensor, PL 11.23 Item 4. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-000 to energize the transport motor 1, MOT11-000. MOT11-000 runs. Y↓N→Go to Flag 2. Check MOT11-000. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J305, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 1, PL 11.14 Item 2. • 2K LCSS PWB, PL 11.26 Item 1. If the fault is still present, perform the 311-319-00-110 Rear Tamper Move Failure RAP. NOTE: A software problem can cause the machine to incorrectly display the fault code 11-142- 110.

Code: 311-140-00-120, 311-142-00-120

Description: Sheet Late to Bin 1 RAP 311-140-00-120 The leading edge of the sheet is late to the 2nd to top exit sensor. 311-142-00-120 The trailing edge of the sheet is late to the 2nd to top exit sensor.
Remedy: NOTE: All 1K LCSS interlocks must be made to supply +24V to the motors.. Enter dC330 code 011-001 transport motor 2, MOT11-001 MOT11-001 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 10, How to check a motor. • P/J16, 1K LCSS PWB. • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 2, PL 11.118 Item 5. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-002 diverter solenoid, SOL11-002 SOL11-002 energizes. Y↓N→Go to Flag 4. Check SOL11-002. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 12, How to Check a Solenoid. • P/J13, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Diverter gate solenoid, PL 11.22 Item 12. • 1K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-140 2nd to top exit sensor, Q11-140. Actuate Q11-140 The display changes. Y↓N→Go to Flag 1. Check Q11-140. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 11, How to Check a sensor. • P/J2, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • 2nd to top exit sensor, PL 11.120 Item 4. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-000 transport motor 1, MOT11-000 MOT11-000 runs. Y↓N→Go to Flag 2. Check MOT11-000. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J17, 1K LCSS PWB. • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 1, PL 11.110 Item 2. • 1K LCSS PWB, PL 11.124 Item 1. Perform SCP 5 Final Actions.

Code: 311-140-00-150, 311-142-00-150

Description: LVF BM Sheet Late to Bin 1 RAP 11-140-00-150 The leading edge of the sheet is late to the 2nd to top exit sensor, Q11-140. 311-142-00-150 The trailing edge of the sheet is late to the 2nd to top exit sensor, Q11-140.
Remedy: NOTE: All LVF BM interlocks must be made to supply +24V to the motors.. Enter dC330, code 011-001 to energize the transport motor 2, MOT11-001. The motor energizes. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • GP 10, How to check a motor. • P/J309, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Transport motor 2, PL 11.70 Item 5. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-002 to energize the diverter solenoid, S11-002. Energize the solenoid. The diverter solenoid energizes. Y↓N→Go to Flag 4. Check SOL11-002. Refer to: • GP 12, How to Check a Solenoid or Clutch. • P/J306, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Diverter gate solenoid, PL 11.22 Item 12. • LVF PWB, PL 11.90 Item 8.. Enter dC330, code 011-140, actuate the 2nd to top exit sensor, Q11-140. The display changes. Y↓N→Go to Flag 1. Check Q11-140. Refer to: • GP 11, How to Check a sensor. • P/J314, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • 2nd to top exit sensor, PL 11.23 Item 4. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-000 to energize the transport motor 1, MOT11-000. The motor energizes. Y↓N→Go to Flag 2. Check MOT11-000. Refer to: • GP 10, How to Check a Motor. • P/J305, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Transport motor 1, PL 11.62 Item 2. • LVF PWB, PL 11.90 Item 8. If the fault is still present, perform 311-319-00-150 Rear Tamper Move Failure RAP.

Code: 311-140-00-171, 311-142-00-171

Description: HVF 2nd to Top Exit Sensor RAP 311-140-00-171 The paper leading edge is late arriving at the 2nd to top exit sensor. 311-142-00-171 The paper trailing edge is late leaving the 2nd to top exit sensor.
Remedy: Enter dC330 code 011-140. Manually activate the 2nd to top exit sensor, Q11-140. The display changes. Y↓N→Go to Flag 1. Check Q11-140. Refer to: • GP 11 How to Check a Sensor. • P/J101, HVF Control PWB • 311A-171 HVF Power Distribution RAP Install new components as necessary: • 2nd to top exit sensor, PL 11.156 Item 2. • HVF control PWB, PL 11.157 Item 2 Enter dC330 code 011-002. Energize the exit diverter solenoid SOL11-002. SOL11-002 energizes. Y↓N→Go to Flag 2. Check SOL11-002. Refer to: • GP 12, How to Check a Solenoid or Clutch. • P/J102, HVF Control PWB • 311A-171 HVF Power Distribution RAP. Install new components as necessary: • Exit diverter solenoid, PL 11.150 Item 4. • HVF control PWB, PL 11.157 Item 2 Enter dC330 code 011-001 to run the transport motor 2, MOT11-001. MOT11-001 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • GP 10 How to Check a Motor. • P/J102, HVF Control PWB • 311A-171 HVF Power Distribution RAP Install new components as necessary: • Transport motor 2, PL 11.150 Item 1. • HVF control PWB, PL 11.157 Item 2 Check the drive belt on the motor. The drive belt is good. Y↓N→Install a new drive belt, PL 11.150 Item 10. The fault may be intermittent, check for damaged wiring or bad connectors. If necessary install new components: • 2nd to top exit sensor, PL 11.156 Item 2. • Exit diverter solenoid, PL 11.150 Item 4. • Diverter gate, PL 11.153 Item 9. • Transport motor 2, PL 11.150 Item 1. • HVF control PWB, PL 11.157 Item 2. • Check if the HVF module has the W/TAG V-006 modifications installed. If the modifications have not been installed perform ADJ 11.13-171 HVF Performance Improvements W/ TAG V-006.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie