Causes: 1 Second side scanning CIS failure. 2 Document scanner unit failure. 3 Main PCB failure
Remedy: 1 Second side scanning CIS failure Replace the second side scanning CIS. 2 Document scanner unit failure Replace the document scanner unit. 3 Main PCB failure Replace the main PCB ASSY.
Description: The document is too long for ADF duplex feeding.
Causes: 1 Document second side rear actuator catching on some position. 2 Main PCB failure
Remedy: 1 Document second side rear actuator catching on some position Correct catching of the document second side rear actuator. 2 Main PCB failure Replace the main PCB ASSY.
Remedy: 1 Harness connection failure of T2 plate motor ASSY Check the harness connection of the T2 plate motor ASSY and reconnect it. 2 Harness connection failure of T2 Relay PCB ASSY Check the harness connection of the T2 Relay PCB ASSY and reconnect it. 3 T2 plate-up detection sensor failure Check the sensor performance following the procedure described in “Function code 32”. If any problem occurs, replace the T2 paper feed frame unit. 4 T2 Relay PCB ASSY failure Replace the T2 Relay PCB ASSY. 5 Engine PCB failure Replace the engine PCB ASSY. 6 T2 plate motor ASSY failure Replace the paper tray 2.