Causes: The detection temperature of the main thermistor did not increase after start of the power distribution to the heater.
Remedy: Replace the fixing assembly. Replace the DC controller PCB
Code: E001-0000
Description: Abnormal high temperature in fixing
Causes: The main thermistor detected a temperature of higher than 255 degree C.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Code: E001-0001
Description: Abnormal high temperature in fixing
Causes: The sub thermistor detected a temperature of higher than 290 degree C.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Code: E001-0004
Description: Abnormal high temperature in fixing
Causes: The sub thermistor 2 detected a temperature exceeding a specified temperature
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Code: E003-0000
Description: Abnormal low temperature in fixing
Causes: The main thermistor detected a temperature of lower than 120 degree C for more than 1 second when 20 seconds elapsed after start of the power distribution to the heater.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Code: E003-0001
Description: Abnormal low temperature in fixing
Causes: The sub thermistor detected a temperature of lower than 80 degree C for more than 2 seconds when 20 seconds elapsed after start of the power distribution to the heater.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Code: E003-0004
Description: Abnormal low temperature in fixing
Causes: The sub thermistor 2 detected a temperature lower than a specified temperature.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.