Causes: Fixing motor startup error The target speed was not reached within a specified time after startup of the motor.
Remedy: Check the contact of the connector between the fixing motor (J516) and the DC controller PCB (J81). Check the gear between the fixing motor and the fixing assembly. Replace the fixing motor.
Code: E014-0001
Description: Fixing motor failure
Causes: Fixing motor rotation error The motor rotated out of the target speed during rotation after the target speed was reached.
Remedy: Check the contact of the connector between the fixing motor (J516) and the DC controller PCB (J81). Check the gear between the fixing motor and the fixing assembly. Replace the fixing motor.
Code: E015-0000
Description: Developing disengagement motor failure
Causes: Developing disengagement motor failure The standard flag was not detected even when driving was performed for 1000ms after rotation of the motor. The standard flag was not detected even when driving was performed for 8000ms at the time of switching from the full-color position to "all disengagement". The standard flag was not detected even when driving was performed for 3000ms at the time of switching from the monochrome position to "all disengagement".
Remedy: Reconnect the connector J518 of the developing disengagement motor, the connector J1005 on the driver PCB, and the connector J91 on the DC controller PCB. Check the condition of the developing disengagement sensor in the sensor monitor mode. If a failure is found, replace the developing disengagement sensor assembly. Execute the developing assembly engagement/disengagement drive test in the actuator drive mode. If the developing assembly does not perform engagement/disengagement, replace the developing disengagement motor.
Code: E015-0001
Description: Cassette 1 lift up motor error
Causes: Cassette 1 lift up motor error
Remedy: Reconnect the connector J151 on the DC controller PCB and the relay connector J742. Check the cassette media stack surface sensor in the sensor monitor mode. If a failure is found, replace the lifter drive unit. Replace the lifter drive unit.
Code: E015-0002
Description: Cassette 2 lift up motor error
Causes: Cassette 2 lift up motor error
Remedy: Reconnect the connector J2003 on the paper feeder driver PCB and the relay connector J702. Check the paper feeder media stack surface sensor in the sensor monitor mode. If a failure is found, replace the pickup unit. Reconnect the connector J2006 on the paper feeder driver PCB. Replace the lifter drive unit.