Các lỗi thường gặp

Code :
  • Code: E010-0002
  • Description: Main Motor (M2) rotation error
    The lock signal was not detected 5 times in a row for 500msec while detecting the signal every 100msec during driving (after the lock signal detection).
  • Remedy: 1. Check the connector connection between the Main Motor (M2) and the DC Controller PCB (PCB1).
    2. Replace the Main Motor (M2).
    3. Replace the DC Controller PCB (PCB1).
  • Code: E013-0000
  • Description: Waste Toner Motor (M3) rotation error
    The same level of the lock signal was detected 375 times in a row while detecting the signal every 2msec.
    * If paper is being fed, the error occurs after the paper has been delivered.
  • Remedy: 1. Check the connector connection between the Waste Toner Motor (M3) and the DC Controller PCB (PCB1).
    2. Replace the Waste Toner Motor (M3).
    3. Replace the DC Controller PCB (PCB1).
  • Code: E014-0001
  • Description: Fixing Motor (M1) rotation error
    The lock signal was not detected for 2.0 seconds while detecting the signal every 100msec since starting the drive of the motor.
  • Remedy: 1. Check the connector connection between the Fixing Motor (M1) and the DC Controller PCB (PCB1).
    2. Replace the Fixing Motor (M1).
    3. Replace the DC Controller PCB (PCB1).
  • Code: E014-0002
  • Description: Fixing Motor (M1) rotation error
    The lock signal was not detected 5 times in a row for 500msec while detecting the signal every 100msec during driving (after the lock signal detection).
  • Remedy: 1. Check the connector connection between the Fixing Motor (M1) and the DC Controller PCB (PCB1).
    2. Replace the Fixing Motor (M1).
    3. Replace the DC Controller PCB (PCB1).
  • Code: E014-0003
  • Description: Fixing Motor (M1) pressure release error
    The pressure release of the Fixing Assembly was not detected for 3.0 seconds during the pressure release drive.
  • Remedy: 1. Check the connector connection between the Fixing Pressure Release Sensor (PS18) or the Fixing Motor (M1) and the DC Controller PCB (PCB1).
    2. Replace the Fixing Pressure Release Sensor (PS18).
    3. Replace the Fixing Motor (M1).
    4. Replace the DC Controller PCB (PCB1).
  • Code: E014-0004
  • Description: Fixing Motor (M1) pressurization error
    The pressurization of the Fixing Assembly was not detected for 3.0 seconds during the pressurization drive.
  • Remedy: 1. Check the connector connection between the Fixing Pressure Release Sensor (PS18) or the Fixing Motor (M1) and the DC Controller PCB (PCB1).
    2. Replace the Fixing Pressure Release Sensor (PS18).
    3. Replace the Fixing Motor (M1).
    4. Replace the DC Controller PCB (PCB1).
  • Code: E020-0000
  • Description: Detection of the toner clog between the Hopper Unit and the Developing Assembly
    When the Developing Assembly Toner Sensor (TS2) detected “toner-absent” and the Hopper Toner Sensor (TS1) detected “toner-present”, the Developing Assembly Toner Sensor (TS2) did not detect “toner-present” though the Hopper Motor (M6) rotated by 194 times at intervals of 1.0 second with having turned on the Developing Cylinder Clutch (CL2).
    * If paper is being fed, the error occurs after the paper has been delivered.
  • Remedy: 1. Check the rotation of the Hopper Motor Gear. (If it is rotating, the sensor may not be detecting correctly. In that case, perform the following to supply toner to the Developing Assembly: COPIER > FUNCTION > INSTALL > TONER-S in the Service Mode.)
    2. Replace the Developing Assembly.
    3. Replace the Hopper Unit.
    4. Replace the DC Controller PCB (PCB1).
  • Code: E024-0001
  • Description: Disconnection of the Developing Assembly Toner Sensor (TS2)
    1. At normal speed: The Developing Assembly Toner Sensor (TS2) signal was detected 7500 times in a row at intervals of 100msec.
    2. At low speed: The Developing Assembly Toner Sensor (TS2) signal was detected 4500 times in a row at intervals of 100msec.
    * If paper is being fed, the error occurs after the paper has been delivered.
  • Remedy: 1. Check the connector connection between the Developing Assembly and the DC Controller PCB (PCB1).
    2. Replace the Developing Assembly.
    3. Replace the DC Controller PCB (PCB1).