Description: Failure of NE Controller Counter
Detection of open circuit of count pulse signal.
Remedy: Disconnection of cable.
Code: E110-0001
Description: Failure of the Polygon Motor (M11)
The Polygon Motor (M11) speed lock signal does not indicate a locked state a specific period of time after the Polygon Motor (M11) has been started. * The same condition is detected after the error retry is performed.
Remedy: 1. Check connection of the Connector (J1/J7/J10/J21/J208/ J8142/J8143). 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB (UN2).
Code: E110-0002
Description: Failure of the Polygon Motor (M11)
The speed lock signal indicates a deviation 10 times in sequence at intervals of 100 msec after the signal has indicated a locked state. * The same condition is detected after the error retry is performed.
Remedy: 1. Check connection of the Connector (J1/J7/J10/J21/J208/ J8142/J8143). 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB (UN2).
Code: E110-0003
Description: Failure of the Polygon Motor (M11)
The Polygon Motor (M11) speed lock signal does not indicate a locked state for 6.5 sec. after a switchover is made from low to normal speed or for 8 sec. after a switchover is made from normal to low speed. * The same condition is detected after the error retry is
Remedy: 1. Check connection of the Connector (J1/J7/J10/J21/J208/ J8142/J8143). 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB (UN2).
Code: E196-0000
Description: Error in EEPROM access
20 retries failed after error occurred during communication with EEPROM. * Error occurs after the delivery if a paper in passage exists.g
Remedy: Replace the DC Controller PCB (UN2).
Code: E196-0001
Description: Main ROM reading/writing error
The main ROM reading or writing error occurs.
Remedy: Replace the DC controller PCB (UN2).
Code: E196-0002
Description: Option ROM reading/writing error
The option ROM reading or writing error occurs.
Remedy: Replace the DC controller PCB (UN2).
Code: E197-0000
Description: Error in communication of Laser Driver PCB Communication time out error between DC Controller PCB and Main Controller PCB 2
Communication error with image PCB (For factory) Communication time out error between DC Controller PCB and Main Controller PCB 2
Remedy: 1. Check the cable. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB (UN2). 4. Replace the Main Controller PCB 2 (UN14)