Các lỗi thường gặp

Code :
  • Code: E027-0001
  • Description: Toner Supply Motor error
    Lock error of the Toner Supply Motor (M10).
  • Remedy: 1. Check the connection of the Connector. Motor side: J2037, Front side relay: J3080, Rear side relay: J3063, Main Driver PCB (PCB2) side: J117 2. Remove the Toner Container, and check if an error occurs. If an error does not occur, reinstall the Toner Container and check again. If an error occurs, check the driving area of connection point of the container. If an error occurs, go on to 3. 3. Replace the Toner Supply Motor (M10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1).
  • Code: E032-0001
  • Description: Failure of NE Controller Counter
    Detection of open circuit of count pulse signal.
  • Remedy: Disconnection of cable.
  • Code: E041-0001
  • Description: Right Deck Lifter Motor error
    Overcurrent of the Right Deck Lifter Motor was detected.
  • Remedy: 1. Check for displacement of the Lifter Wire of the Right Deck. 2. Check for hindrance to smooth movement of the Deck Base Plate of the Right Deck.
  • Code: E041-0002
  • Description: Left Deck Lifter Motor error
    Overcurrent of the Leftt Deck Lifter Motor was detected.
  • Remedy: 1. Check for displacement of the Lifter Wire of the Left Deck. 2. Check for hindrance to smooth movement of the Deck Base Plate of the Left Deck.
  • Code: E041-0003
  • Description: Cassette 3 Lifter Motor error
    Overcurrent of the Cassette 3 Lifter Motor was detected.
  • Remedy: 1. Check for error around the Lifter of the Cassette 3. 2. Check for hindrance to smooth movement of the Cassette Base Plate of the Cassette 3.
  • Code: E041-0004
  • Description: Cassette 4 Lifter Motor error
    Overcurrent of the Cassette 4 Lifter Motor was detected.
  • Remedy: 1. Check for error around the Lifter of the Cassette 4. 2. Check for hindrance to smooth movement of the Cassette Base Plate of the Cassette 4.
  • Code: E053-0001
  • Description: Error in Reverse Upper Flapper Solenoid connection detection
    Connection of the Reverse Upper Flapper Solenoid (SL5) cannot be detected 5 times with 20 msec time interval.
  • Remedy: 1. Check the connection of the Reverse Upper Flapper Solenoid (SL5). Solenoid side: J2115, Duplex Driver PCB side: J340 2. Replace the Reverse Upper Flapper Solenoid (SL5). 3. Replace the Duplex Driver PCB (PCB4). 4. Replace the DC Controller PCB (PCB1).
  • Code: E060-0001
  • Description: Primary Charging Shutter HP open error
    The Primary Charging Shutter Sensor (PS94) detects that the shutter is opened although it is moved to the close position.
  • Remedy: 1. Check the position of the Primary Charging Shutter and the Cleaning Pad. 1-A. In the case that the Primary Charging Shutter and the Cleaning Pad fail to operate (stopped at HP at front side) 1-A-1. Check the connection of the Primary Charging Wire Cleaning Motor (M6). Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV 6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2)) 1-A-2. Replace the Primary Charging Wire Cleaning Motor (M6). 1-B. In the case that the Primary Charging Shutter and the Cleaning Pad are stopped at rear side (close operation position) 1-B-1. Check the connection of the Primary Charging Shutter Sensor (PS94). Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2)) 1-B-2. Replace the Primary Charging Shutter Sensor (PS94). 1-C. In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way 1-C-1. Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin. 1-C-2. Replace the Primary Charging Assembly. 1-D. In the case that the Primary Charging Shutter stops at front side and the Cleaning Pad moves to rear side 1-D-1. Check if the Shutter Mounting Plate is deformed. If so, replace the Shutter Unit. 1-D-2. Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin. 1-D-3. Replace the Primary Charging Assembly. 2. Replace the Main Driver PCB (PCB2). 3. Replace the DC Controller PCB (PCB1).