Các lỗi thường gặp

Code :
  • Code: 532-8002-02
  • Description: Error in the Stapler Shift Motor (Finisher-V1)
  • Causes: The Stapler Shift HP Sensor does not detect the stapler unit when the Stapler Shift Motor has been driven for 15 seconds.
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Stapler Shift HP Sensor (PS124) to the Finisher Controller PCB - Harnesses from the Stapler Shift Motor (M114) to the Finisher Controller PCB - Stapler Shift HP Sensor (PS124) - Stapler Shift Motor (M114) - Finisher Controller PCB (PCB101) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 533-8001-02
  • Description: Staple-free Binding Motor Clock error (Finisher-V1)
  • Causes: The clock signal from the Staple-free Binding Motor Clock Sensor does not detect during from 0.24 seconds to 0.25 seconds after operating the Staple-free Binding Motor.
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Staple-free Binding Unit to the Finisher Controller PCB - Staple-free Binding Unit - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 533-8002-02
  • Description: Error in the Staple-free Binding Motor (Finisher-V1)
  • Causes: The staple-free binding unit does not come off the Staple-free Binding HP Sensor when the Staplefree Binding Motor has been driven for 0.25 seconds.
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Staple-free Binding Unit to the Finisher Controller PCB - Staple-free Binding Unit - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 533-8003-02
  • Description: Error in the Staple-free Binding Motor (Finisher-V1)
  • Causes: The clock signal from the Staple-free Binding Motor Clock Sensor does not detect during from 0.24 seconds to 0.25 seconds after operating the Staple-free Binding Motor, and the staple-free binding unit does not come off the Staple-free Binding HP Sensor when the Staple-free Binding Motor has been driven for 0.25 seconds.
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Staple-free Binding Unit to the Finisher Controller PCB - Staple-free Binding Unit - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 533-8004-02
  • Description: Staple-free binding time out error (Finisher-V1)
  • Causes: The staple-free binding does not be executed within 2 seconds after starting the operation. (The rotation speed of the motor that detected by the Staple-free Binding Motor Clock Sensor don't decrease.)
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Staple-free Binding Unit to the Finisher Controller PCB - Staple-free Binding Unit - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 533-8005-02
  • Description: Error in the Staple-free Binding Motor (Finisher-V1)
  • Causes: The Staple-free Binding HP Sensor does not detect the staple-free binding part when the Staplefree Binding Motor has been driven. (The return operation of the binding parts isn't completed.)
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Staple-free Binding Unit to the Finisher Controller PCB - Staple-free Binding Unit - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 535-8001-02
  • Description: Error in the Swing Guide Motor (Finisher-V1)
  • Causes: The swing guide does not come off the Swing Guide HP Sensor when the Swing Guide Motor has been driven for 1 second.
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Swing Guide HP Sensor (PS119) to the Finisher Controller PCB - Harnesses from the Swing Guide Motor (M110) to the Finisher Controller PCB - Swing Guide HP Sensor (PS119) - Swing Guide Motor (M110) - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.
  • Code: 535-8002-02
  • Description: Error in the Swing Guide Motor (Finisher-V1)
  • Causes: The Swing Guide HP Sensor does not detect the swing guide when the Swing Guide Motor has been driven for 1 second.
  • Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Swing Guide HP Sensor (PS119) to the Finisher Controller PCB - Harnesses from the Swing Guide Motor (M110) to the Finisher Controller PCB - Swing Guide HP Sensor (PS119) - Swing Guide Motor (M110) - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.