Các lỗi thường gặp

Code :
  • Code: E240-0005
  • Description: Communication data error
    60 sec has passed while waiting for the start of auto adjustment at warm-up rotation
  • Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
  • Code: E240-0006
  • Description: Communication data error
    Data access error
  • Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
  • Code: E240-0007
  • Description: Communication data error
    Time notification error
  • Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
  • Code: E246
  • Description: System error
  • Remedy: Contact the service company office
  • Code: E247
  • Description: System error
  • Remedy: Contact the service company office
  • Code: E248-0001
  • Description: EEPROM error (Scanner Unit)
    An error has occurred at power-on.
  • Remedy: 1.Disconnect and then connedt the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)50pin). 2.Disconnect and then connect the flexible cable(Scanner Unit- Relay PCB(PCB1)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the Scanner Unit. 6.Replace the Relay PCB(PCB1) 7.Replace the Power Supply PCB(PCB1). 8.Replace the Main Controller2 PCB(UN12).
  • Code: E248-0002
  • Description: EEPROM error (Scanner Unit)
    An error has occurred during write operation.
  • Remedy: 1.Disconnect and then connedt the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)50pin). 2.Disconnect and then connect the flexible cable(Scanner Unit- Relay PCB(PCB1)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the Scanner Unit. 6.Replace the Relay PCB(PCB1) 7.Replace the Power Supply PCB(PCB1). 8.Replace the Main Controller2 PCB(UN12).
  • Code: E248-0003
  • Description: EEPROM error (Scanner Unit)
    An error has occurred during read operation following write operation.
  • Remedy: 1.Disconnect and then connedt the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)50pin). 2.Disconnect and then connect the flexible cable(Scanner Unit- Relay PCB(PCB1)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the Scanner Unit. 6.Replace the Relay PCB(PCB1) 7.Replace the Power Supply PCB(PCB1). 8.Replace the Main Controller2 PCB(UN12).