Description: Fax Board communication error. An error occurred in the modem IC used for fax.
Remedy: [Related parts] • Harness between the Fax Board and the Main Controller PCB (UN05/J30) (Unit of replacement: CABLE, SIGNAL) • Fax Board • Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts.
Description: Fax Board communication error. After completion of fax communication, writing of the communication information (log) failed, and the log could not be read.
Remedy: [Remedy] Turn OFF and then ON the main power. [CAUTION] The previous communication information (log) will be cleared by turning OFF and then ON the main power.
Description: HDD access error. An error occurred when accessing the HDD.
Remedy: [Related parts] • HDD (Unit of replacement: HARD DISK DRIVE) • Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. After deleting the system software using a USB memory, reinstall it using SST or a USB memory. 2. After replacing the HDD, execute [4] Clear/Format> [1] Disk Format (HDD format) using SST or a USB memory. 3. Replace the Main Controller PCB.
Description: Communication error. Communication between the DC Controller PCB and the Finisher timed out.
Remedy: [Related parts] a. STAPLE/BOOKLET FINISHER-U1 • Harnesses from the DC Controller PCB to the Finisher Controller PCB 1. DC Controller PCB (UN04/J182) to Relay Path Unit (Unit of replacement: CABLE, PRIMARY TRANSFER H.V.) 2. Relay Path Unit to Finisher Controller PCB • Harness between the Low Voltage Power Supply PCB (UN01/ J306) and the Relay Path Unit (J1186) (Unit of replacement: CABLE, HEATER) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Relay Path Unit • Finisher Controller PCB • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES b. INNER FINISHER-G1 • Harnesses from the DC Controller PCB to the Finisher Controller PCB 1. DC Controller PCB (UN04/J182) to Relay Path Unit (Unit of replacement: CABLE, PRIMARY TRANSFER H.V.) 2. Relay Path Unit to Finisher Controller PCB • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Relay Path Unit • Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Communication error. A communication error between the DC Controller PCB and the Finisher was detected.
Remedy: [Related parts] a. STAPLE/BOOKLET FINISHER-U1 • Harnesses from the DC Controller PCB to the Finisher Controller PCB 1. DC Controller PCB (UN04/J182) to Relay Path Unit (Unit of replacement: CABLE, PRIMARY TRANSFER H.V.) 2. Relay Path Unit to Finisher Controller PCB • Harness between the Low Voltage Power Supply PCB (UN01/ J306) and the Relay Path Unit (J1186) (Unit of replacement: CABLE, HEATER) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Relay Path Unit • Finisher Controller PCB • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES b. INNER FINISHER-G1 • Harnesses from the DC Controller PCB to the Finisher Controller PCB 1. DC Controller PCB (UN04/J182) to Relay Path Unit (Unit of replacement: CABLE, PRIMARY TRANSFER H.V.) 2. Relay Path Unit to Finisher Controller PCB • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Relay Path Unit • Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Communication error. A communication error between the DC Controller PCB and the Finisher was detected
Remedy: [Related parts] a. STAPLE/BOOKLET FINISHER-U1 • Harnesses from the DC Controller PCB to the Finisher Controller PCB 1. DC Controller PCB (UN04/J182) to Relay Path Unit (Unit of replacement: CABLE, PRIMARY TRANSFER H.V.) 2. Relay Path Unit to Finisher Controller PCB • Harness between the Low Voltage Power Supply PCB (UN01/ J306) and the Relay Path Unit (J1186) (Unit of replacement: CABLE, HEATER) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Relay Path Unit • Finisher Controller PCB • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES b. INNER FINISHER-G1 • Harnesses from the DC Controller PCB to the Finisher Controller PCB 1. DC Controller PCB (UN04/J182) to Relay Path Unit (Unit of replacement: CABLE, PRIMARY TRANSFER H.V.) 2. Relay Path Unit to Finisher Controller PCB • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Relay Path Unit • Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.