Description: Error due to non-compatible Finisher. A finisher which cannot be connected to the host machine was detected
Remedy: [Remedy] Connect the finisher (INNER FINISHER-G1, BOOKLET/STAPLE FINISHER-U1) for this model
Code: E730 A006
Description: PDL communication error. Response from PDL could not be detected
Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Select "Settings/Registration> Function Settings> Printer> Printer Settings> Utility> Initialize Printer", and execute PDL reset processing. 2. Reinstall the system software. 3. Replace the Main Controller PCB (UN05). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
Code: E730 A007
Description: Mismatch of PDL version. Version of the host machine control software and version of PDL control software were different
Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Reinstall the system software. 2. Replace the Main Controller PCB (UN05). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
Code: E730 B013
Description: PDL embedded font error. Font data was corrupted.
Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Reinstall the system software. 2. Replace the Main Controller PCB (UN05). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
Code: E732 0001
Description: Scanner communication error. DDI-S communication error was detected.
Remedy: [Related parts] • Flat Cable between the Main Controller PCB (UN05/J33) and the Scanner Unit (Unit of replacement: CABLE, FLAT) • Scanner Unit (Unit of replacement: LASER SCANNER ASSEMBLY) • Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts.
Code: E732 0010
Description: Scanner communication error. DDI-S communication error (Vsync detection error) was detected.
Remedy: [Related parts] • Flat Cable between the Main Controller PCB (UN05/J33) and the Scanner Unit (Unit of replacement: CABLE, FLAT) • Scanner Unit (Unit of replacement: LASER SCANNER ASSEMBLY) • Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts
Code: E733 0000
Description: Printer communication error. A communication error between the DC Controller PCB and the Main Controller PCB was detected at startup.
Remedy: [Related parts] • Harness between the DC Controller PCB (UN04/J110) and the Main Controller PCB (UN05/J18) (Unit of replacement: DDIP, CABLE) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E733 0001
Description: Printer communication error. • DDI-P communication error • DDI-L communication error (parity error)
Remedy: [Related parts] • Harness between the DC Controller PCB (UN04/J110) and the Main Controller PCB (UN05/J18) (Unit of replacement: DDIP, CABLE) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES