Các lỗi thường gặp

Code :
  • Code: E996 0CB6
  • Description: Error for collecting sequence jam log (Printer). Error for collecting jam log (Printer) Continuous 0CB6 jam was detected
  • Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence
  • Code: E996 0CB8
  • Description: Error for collecting sequence jam log (Printer). Error for collecting jam log (Printer) Continuous 0CB8 jam was detected.
  • Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence.
  • Code: E996 0CF0
  • Description: Error for collecting sequence jam log (Printer). Error for collecting jam log (Printer) Continuous 0CF0 jam was detected.
  • Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence
  • Code: E996 0CF3
  • Description: Error for collecting sequence jam log (Printer). Error for collecting jam log (Printer) Continuous 0CF3 jam was detected
  • Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence
  • Code: E996 0CF4
  • Description: Error for collecting sequence jam log (Printer). Error for collecting jam log (Printer) Continuous 0CF4 jam was detected.
  • Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence
  • Code: E996 0CF5
  • Description: Error for collecting sequence jam log (Printer). Error for collecting jam log (Printer) Continuous 0CF5 jam was detected.
  • Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence