Code :
  • Code: E732-0001
  • Description: Scanner communication error
    DDI-S communication error.
  • Remedy: [Related parts] - Flexible Cable between the Scanner Unit (CIS01, CIS02/ J911) and the Main Controller PCB (UN81/J8101) (Unit of replacement: CABLE, FLAT) - Scanner Unit (CIS01/CIS02) (Unit of replacement: CONTACT IMAGE SENSOR ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
  • Code: E732-0010
  • Description: Scanner communication error
    DDI-S communication error (Vsync detection error)
  • Remedy: [Related parts] - Flexible Cable between the Scanner Unit (CIS01, CIS02/ J911) and the Main Controller PCB (UN81/J8101) (Unit of replacement: CABLE, FLAT) - Scanner Unit (CIS01/CIS02) (Unit of replacement: CONTACT IMAGE SENSOR ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
  • Code: E733-0000
  • Description: Printer communication error
    Communication between the DC Controller PCB and the Main Controller PCB was not available at startup.
  • Remedy: [Related parts] - DC Controller PCB (UN04/J20) and the Harness between the Low-voltage Power Supply PCB (UN01/J315) (Unit of replacement: CABLE, POWER SUPPLY) - Flexible Cable between the DC Controller PCB (UN04/ J112) and the Main Controller PCB (UN81/J7001) (Unit of replacement: CABLE, FLAT) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Low-voltage Power Supply PCB. 2. Check the harness between the DC Controller PCB and the Main Controller PCB. 3. Turn ON the power, and check if the initialization is executed at startup. 3-1. If the initialization is not executed, replace the DC Controller PCB. 3-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E733-0001
  • Description: Printer communication error
    - DDI-P communication error - DDI-L communication error (parity error)
  • Remedy: [Related parts] - Flexible Cable between the DC Controller PCB (UN04/ J112) and the Main Controller PCB (UN81/J7001) (Unit of replacement: CABLE, FLAT) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E733-0002
  • Description: Printer communication error
    DDI-P communication error (invalid packet)
  • Remedy: [Related parts] - Flexible Cable between the DC Controller PCB (UN04/ J112) and the Main Controller PCB (UN81/J7001) (Unit of replacement: CABLE, FLAT) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E733-0F00
  • Description: Printer communication erro
    rA communication error that can be recovered by reboot. If it is detected again after reboot, E733-0000 is generated.
  • Remedy: [Remedy] It is not necessary to perform a remedy because the machine is automatically rebooted after log collection.
  • Code: E733-0F01
  • Description: Printer communication error
    A communication error that can be recovered by reboot. If it is detected again after reboot, E733-0001 is generated.
  • Remedy: [Remedy] It is not necessary to perform a remedy because the machine is automatically rebooted after log collection.
  • Code: E733-0F02
  • Description: Printer communication error
    A communication error that can be recovered by reboot. If it is detected again after reboot, E733-0002 is generated.
  • Remedy: [Remedy] It is not necessary to perform a remedy because the machine is automatically rebooted after log collection.