Các lỗi thường gặp

Code :
  • Code: E227-0001-04
  • Description: Power supply error
  • Causes: The Main Controller PCB did not detect 24 V when the main power was turned ON.
  • Remedy: [Related parts] R1.00 - Harness between the Main Controller PCB (UN81/J4509) and the Low-voltage Power Supply PCB (UN01/J313) - Low-voltage Power Supply PCB (UN01) - Main Controller PCB (UN81) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E240-0000-05
  • Description: Controller communication error
  • Causes: A communication error occurred between the Main Controller PCB and the DC Controller PCB.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - DC Controller PCB (UN04) - Main Controller PCB (UN81) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E240-0002-00
  • Description: Controller communication error
  • Causes: An error in receiving data from the controller was detected.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - DC Controller PCB (UN04) - Main Controller PCB (UN81) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E240-0005-00
  • Description: Controller communication error
  • Causes: A sequence error with the controller occurred.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - DC Controller PCB (UN04) - Main Controller PCB (UN81) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E240-0D00-00
  • Description: Controller communication error
  • Causes: A sequence error with the controller occurred.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - DC Controller PCB (UN04) - Main Controller PCB (UN81) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the harness between the DC Controller PCB and the Main Controller PCB. 2. Turn ON the power, and check if the initialization is executed at startup. 2-1. If the initialization is not executed, replace the DC Controller PCB. 2-2. If the initialization is executed, replace the Main Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E246-0001-00
  • Description: System error
  • Causes: System error
  • Remedy: Contact to the sales company.
  • Code: E246-0002-00
  • Description: System error
  • Causes: System error
  • Remedy: Contact to the sales company.
  • Code: E246-0003-00
  • Description: System error
  • Causes: System error
  • Remedy: Contact to the sales company.