Các lỗi thường gặp

Code :
  • Code: E008-0001
  • Description: Pressure belt unit life detection error. The amount of fixing motor current reached the specified value due to torque-up of the pressure belt. Or, the temporary mode for prevention of belt displacement was executed, but displacement was not eliminated.
  • Remedy: 1. Confirm the current value is 80 (0.8A) and below on the service mode (DISPLAY > FIXING > FX-MTR8). A. In case that the current value is "smaller than 80" A-1. The pressure belt unit reaches to its life -> replace the pressure belt unit A-2. Faulty fixing unit drive gear -> replace the gear A-3. Fault fixing motor (M48) B. In case that the current value is "80 and larger" B-1. Faulty fixing unit drive gear -> replace the gear B-2. Faulty fixing motor (M48) -> replace the fixing mtoor B-3. Fault relay PCB -> replace it 2. Clear the current value log of fixing motor on the service mode after procedure. COPIER > FUNCTION > CLEAR > FX-L-CLR
  • Code: E008-0002
  • Description: Fixing belt unit life detection error. Total rotation time of the fixing belt reached 15,000 hours.
  • Remedy: 1. The fixing belt unit reaches to its life -> replace the fixing belt unit
  • Code: E008-0003
  • Description: Fixing belt unit life detection error. Page count for the fixing belt reached to the 400,000 sheets.
  • Remedy: 1. The fixing belt unit reaches to its life -> replace the fixing belt unit
  • Code: E009-0500
  • Description: Pressure unit pressure release HP search error. The home position for rotation of releasing pressure of the fixing assembly could not be detected.
  • Remedy: 1. Check the fixing pressure release drive gear -> replace the gear 2. Replace the fixing pressure release sensor (PS73) 3. Replace the fixing pressure release motor (M47) 4. Replace the fixing feed driver PCB 5. Replace the DC controller PCB
  • Code: E009-0501
  • Description: Pressure unit pressure release timeout error. Pressure release operation could not be completed within a specified period.
  • Remedy: 1. Check the fixing pressure release drive gear -> replace the gear 2. Replace the fixing pressure release sensor (PS73) 3. Replace the fixing pressure release motor (M47) 4. Replace the fixing feed driver PCB 5. Replace the DC controller PCB
  • Code: E009-0502
  • Description: Pressure unit pressure application timeout error. Pressure application operation could not be completed within a specified period.
  • Remedy: 1. Check the fixing pressure release drive gear -> replace the gear 2. Replace the fixing pressure release sensor (PS73) 3. Replace the fixing pressure release motor (M47) 4. Replace the fixing feed driver PCB 5. Replace the DC controller PCB
  • Code: E012-0101
  • Description: A.Drum Speed Detection PCB (Y) 1/2 signal error (Controller Version 2x.xx or later) B.Drum motor (Y) error (Prior to Controller Version 1x.xx). A:This error occurs when the Drum Speed Detection PCB (Y) 1/2 signal error is detected. B:The lock signal for the drum motor (Y) (M21) cannot be detected within a specified period.Connector disconnected, Breaking (Breaking (shorting)) - Connector disconnected, Breaking (Breaking (shorting)) - Drum (unit) not inserted - Drum unit failure - Encoder failure (This occurs in very rare cases.)
  • Remedy: A: 1. Check the connection of the Drum Speed Detection PCB (Y) 1/2 (UN20/21). (Sensor side) Sensor side: J7316, J7317, J8016 2. Check that the Encoder Wheel of the Drum Speed Detection PCB (Y) 1/2 is properly installed. 3. Check the connection of the Drum ITB Driver PCB (UN6). PCB side: J1910 4. Take out the Drum Speed Detection PCB (Y) 1/2 to clean the Drum Speed Detection PCB (Y) 1/2 (UN20/21) and Encoder Wheel. 5. Replace the Drum Speed Detection PCB (Y) 1/2 (UN20/21). 6. Replace the Drum ITB Driver PCB (UN6). B: 1. Check the connection between the drum motor (Y) (M21) and the drum ITB driver PCB (UN6). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7300/J8019, PCB side: J1920 2. Check the connection between the drum speed detection PCB (Y) (UN20/21) and the drum ITB driver PCB (UN6). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7316/J7317/J8016, PCB side: J1910 3. Reinstall the drum unit (Y). 4. Replace the drum unit. (Drum drive may be overloaded due to peeling of the blade, etc.) 5. Replace the drum ITB driver PCB (UN6). MEMO: In some rare cases, this error occurs when the encoder is not installed with the drum speed detection PCB or when dirt is applied to the sensor surface of the drum speed detection PCB.
  • Code: E012-0102
  • Description: A.Drum Speed Detection PCB (Y) 1 signal error (Controller Version 2x.xx or later) B.Drum motor (Y) error (Prior to Controller Version 1x.xx). A.The signal is not detected for 80msec or more. B.Lock signal of Drum motor (Y)(M21) cannot be detected for the specified time after first detection - Connector disconnected, Breaking (Breaking (shorting)) - Drum (unit) not inserted - Drum unit failure - Encoder failure (This occurs in very rare cases.)
  • Remedy: A: 1. Check the connection of the Drum Speed Detection PCB (Y) 1 (UN20). Sensor side: J7316, J8016 PCB side:J1910 2. Take out the Drum Speed Detection PCB (Y) 1 (UN20) to clean. 4. Replace the Drum Speed Detection PCB (Y) 1 (UN20). 5. Check if the Harness of the Drum Speed Detection PCB (Y) 1 (UN20) is faulty. (Replace the Harness if it's disconnected.) 6. Replace the Drum ITB Driver PCB (UN6). B: 1. Check the connection between the drum motor (Y) (M21) and the drum ITB driver PCB (UN6). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7300/J8019, PCB side: J1920 2. Check the connection between the drum speed detection PCB (Y) (UN20/21) and the drum ITB driver PCB (UN6). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7316/J7317/J8016, PCB side: J1910 3. Reinstall the drum unit (Y). 4. Replace the drum unit. (Drum drive may be overloaded due to peeling of the blade, etc.) 5. Replace the drum ITB driver PCB (UN6).