Description: Error in the saddle lead-in roller disengage motor (Finisher-K1). The saddle lead-in roller does not come off the saddle lead-in roller HP sensor when the saddle lead-in roller disengage motor has been driven for 50 pulses.
Remedy: 1. The connector of the saddle lead-in roller HP sensor (S222) or the saddle lead-in roller disengage motor (M214) are disconnected. 2. The wiring of the saddle lead-in roller HP sensor/the saddle lead-in roller disengage motor are faulty. 3. The saddle lead-in roller HP sensor is faulty. 4. The saddle lead-in roller disengage motor is faulty. 5. The saddle stitcher controller PCB is faulty. 6. The finisher controller PCB is faulty.
Code: E602-0001
Description: Error in HDD. HDD failed to be recognized. Startup partition (BOOTDEV) failed to be found at startup.
Remedy: 1. Turn OFF the main switch and check connection of HDD cable, and then turn ON the main switch. 2. If the Encryption Board has been installed, there may be an Encryption Board failure. In this case, disconnect the signal cable connecting to the Encryption Board and directly connect to the HDD. (It cannot be connected from the back side. Open the Main Controller Cover, and connect by going over the Main Controller PCB 1.) After connecting, power on by the safe mode. If the machine starts normally, replace the Encryption Board as the Encryption Board had failed. 3. Be sure that HDD spins stably (no problem in drive sound) and 5V/12V power is supplied when the main power is turned ON. (If the drive sound is abnormal, replace the HDD.) 4. Replace the HDD and reinstall the system. (In the case of using a USB memory device, insert a USB memory device where the system software has been registered to the slot of the host machine, and then execute main menu [3]: Upgrade (Overwrite all).) 5. Replace the Main Controller PCB 1.
Code: E602-0002
Description: Error in HDD. There is no system for the main CPU
Remedy: 1. Start in Safe Mode, then perform overall format using SST or USB memory and reinstall the system, and then turn OFF and then ON the Main Switch. (Prepare the USB memory which system software was registered. Insert the USB memory to the equipment. Execute [3]: Upgrade (Overwrite All) in the main menu.) 2. If the above measures do not solve the problem, it can be caused by failure with HDD; therefore, replace the HDD and reinstall the system.
Code: E602-0003
Description: Error in HDD. WriteAbort was detected with BootDevice
Remedy: 1. Execute detection and recovery of WriteAbortSector <In the case of display of B/W E-code> 1-1. Perform the following steps because Service Mode is not available. 1-2. Turn OFF the power. Then, while pressing 1+9 keys, turn ON the power. WriteAbortSector recovery routine is automatically started which makes the screen black. 1-3. After a while, progress is displayed because the process takes time (40 to 50 min.). The process is complete when the screen turns white. <In the case of official display of wrench-mark> 1-1. Set as follows: CHK-TYPE=0; and execute HD-CHECK (40 to 50 min.), and then turn OFF and then ON the main switch. 2. If the above measures do not solve the problem, start up in Safe Mode to perform overall format using SST or USB memory and reinstall the system, and then turn OFF and then ON the main switch. 3. If no improvement is found despite the above measures, it can be caused by failure with HDD; therefore, replace the HDD and reinstall the system.
Code: E602-0006
Description: Error in HDD. There is no system for the sub CPU
Remedy: Reinstall the system software. For details, see “Chapter 6: Upgrading”. For your reference, the method using USB memory is described below. 1. Prepare the USB memory which system software was registered. 2. Execute the following service mode: COPIER>FUNCTION>SYSTEM>DOWNLOAD to enter the download mode. (When it is not operated normally, start the safe mode.) 3. Insert the USB memory to the equipment. 4. Execute [3]: Upgrade (Overwrite All) in the main menu. (Be sure to download SYSTEM, LANGUAGE and RUI.) 5. System software is downloaded and the machine restarts automatically. At this time, if the machine restarts with the safe mode, E753 might occurs. Check the log. In case of the system software of the options which are not connected, turn OFF and then ON the power supply to restore. (For details, see the description for E753.) If the measures above do not solve the problem, replace the HDD and download the system software with the foregoing method.
Code: E602-0007
Description: Error in HDD. There is no ICCProfile
Remedy: 1. Start up in Safe Mode and reinstall the system using SST; and then turn OFF and then ON the main power switch. 2. If the above measures do not solve the problem, it can be caused by failure with the HDD; therefore, replace the HDD and reinstall the system.
Code: E602-0009
Description: Error in HDD. There is no Font file in /BOOTDEV/BOOT
Remedy: 1. Start up in Safe Mode and reinstall the system using SST; and then turn OFF and then ON the main power switch. 2. If the above measures do not solve the problem, it can be caused by failure with the HDD; therefore, replace the HDD and reinstall the system.
Code: E602-001
Description: Error in HDD. There is no Chinese, Korean, and Taiwan font files
Remedy: 1. Start up in Safe Mode and reinstall the system using SST; and then turn OFF and then ON the main power switch. 2. If the above measures do not solve the problem, it can be caused by failure with the HDD; therefore, replace the HDD and reinstall the system.