Các lỗi thường gặp

Code :
  • Code: 013-0001-05
  • Description: Waste toner full detection error
  • Causes: The Screw Lock Switch in the Waste Toner Pipe detected locked state.
  • Remedy: [Related parts] R1.00 - Harness between the Drum Driver PCB (UN6/J1911) and the Waste Toner Screw Lock Detection Switch (SW10) - Harness between the Multi Driver PCB (UN97/J1351) and the Drum Cleaning and Waste Toner Feed Drive Motor (M30/J7539) - Waste Toner Screw Lock Detection Switch (SW10) - Waste Toner Container - Waste Toner Feed Drive Unit - Drum Driver PCB (UN6) - Multi Driver PCB (UN97) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Remove the clogged toner in the Waste Toner Pipe. 2. Check/replace the related harness/cable, connector and parts.
  • Code: 013-0003-05
  • Description: Waste toner full detection error
  • Causes: Output was detected while the Waste Toner Full Sensor was OFF.
  • Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1483) and the Waste Toner Full Sensor (TS9/ J8981) - Waste Toner Full Sensor (TS9) - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 014-0001-05
  • Description: Fixing Motor error
  • Causes: The Fixing Motor did not show the lock state although 3 sec have passed after it was turned ON or the speed was changed.
  • Remedy: [Related parts] R1.00 - Harness between the Fixing Feed Driver PCB (UN5/J1507) and the Fixing Motor (M48/J7217) - Harnesses connecting the Relay PCB (UN7/J1816), the Drawer Unit (J8023) and the Fixing Motor (M48/J7612) - Fixing Motor (M48) - Fixing Feed Driver PCB (UN5) - Relay PCB (UN7) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the Fixing Motor can be rotated by hand. If not, replace the Fixing Motor. 2. Check/replace the related harness/cable, connector and parts.
  • Code: 014-0002-05
  • Description: Fixing Motor error
  • Causes: The Fixing Motor was unlocked for 1 sec after it was locked.
  • Remedy: [Related parts] R1.00 - Harness between the Fixing Feed Driver PCB (UN5/J1507) and the Fixing Motor (M48/J7217) - Harnesses connecting the Relay PCB (UN7/J1816), the Drawer Unit (J8023) and the Fixing Motor (M48/J7612) - Fixing Motor (M48) - Fixing Feed Driver PCB (UN5) - Relay PCB (UN7) - Fixing Drive System Gears [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Visually check the gears of the fixing drive system for any damage or abnormal abrasion. If there is any problem, replace the gear. 2. Check/replace the related harness/cable, connector and parts.
  • Code: 015-0003-05
  • Description: Pre-registration disengagement HP timeout error
  • Causes: Change in home position within the specified period of time was not detected after startup of the Pre-registration Disengagement Motor.
  • Remedy: [Related parts] R1.00 - Harness between the Fixing Feed Driver PCB (UN5/J1512) and the Pre-registration Disengagement HP Sensor (PS137/J8622) - Harness between the Fixing Feed Driver PCB (UN5/J1514) and the Pre-registration Disengagement Motor (M92/J8625) - Pre-registration Disengagement HP Sensor (PS137) - Pre-registration Motor (M92) - Fixing Feed Driver PCB (UN5) - Registration Unit [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 015-0004-05
  • Description: Pre-registration disengagement HP timeout error
  • Causes: Change in home position within the specified period of time was not detected while the Preregistration Disengagement Motor was in operation.
  • Remedy: [Related parts] R1.00 - Harness between the Fixing Feed Driver PCB (UN5/J1512) and the Pre-registration Disengagement HP Sensor (PS137/J8622) - Harness between the Fixing Feed Driver PCB (UN5/J1514) and the Pre-registration Disengagement Motor (M92/J8625) - Pre-registration Disengagement HP Sensor (PS137) - Pre-registration Motor (M92) - Fixing Feed Driver PCB (UN5) - Registration Unit [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 020-01A8-05
  • Description: Toner Density Sensor (Y) output upper/lower limit error
  • Causes: Output (Vsig_ind) of the Toner Density Sensor (Y) showed 245 or higher or 10 or lower once during operation.
  • Remedy: [Related parts] R1.00 - Harness between the Side Driver PCB (UN96/J1305) and the Toner Density Sensor (Y) (TS2/ J8944) - Toner Density Sensor (Y) (TS2) - Side Driver PCB (UN96) - Developing Assembly (Y) [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 020-01B8-05
  • Description: Toner Density Sensor (Y) output upper/lower limit error
  • Causes: When executing the initial installation mode of the Developing Assembly (Y) (COPIER> FUNCTION> INSTALL> INISET-Y), output failed to reach 128 although the control voltage value of the Toner Density Sensor (Y) reached 1023 or higher. Or output failed to reach 128 although the control voltage reached 220 or lower.
  • Remedy: [Related parts] R1.00 - Harness between the Side Driver PCB (UN96/J1305) and the Toner Density Sensor (Y) (TS2/ J8944) - Toner Density Sensor (Y) (TS2) - Side Driver PCB (UN96) - Developing Assembly (Y) [Remedy] Check/replace the related harness/cable, connector and parts.