Code: 260-1432-05

Description: Power supply error
Causes: The 24 V supply to the motor or solenoid was not detected. (Blowout of FU4 and 5 on the Multipurpose Tray Pickup Driver PCB)
Remedy: [Related parts] R1.00 - Harness connecting from the Multi-purpose Tray Pickup Driver PCB (UN97/J1359) to the Multipurpose Tray Lifter Motor, Multi-purpose Tray Pickup Motor and Multi-purpose Tray Pickup Solenoid (M90/J8544, M91/J8545 and SL10/J8546) - Multi-purpose Tray Lifter Motor (M90) - Multi-purpose Tray Pickup Motor (M91) - Multi-purpose Tray Pickup Solenoid (SL10) - Multi-purpose Tray Pickup Driver PCB (UN97) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 260-1472-05

Description: Power supply error
Causes: The 24 V supply to the Decurler Advancement Adjusting Motor was not detected. (Blowout of FU3 on the Buffer Driver PCB)
Remedy: [Related parts] R1.00 - Harness between the Buffer Driver PCB (UN98/J2104) and the Decurler Advancement Adjusting Motor (M53/J5102) - Decurler Advancement Adjusting Motor (M53) - Buffer Driver PCB (UN98) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 260-2511-05

Description: Power supply error
Causes: The 5 V supply to the sensor or the 24 V supply to the solenoid and motor was not detected. (Blowout of FU9, 10, 11, 16, 17, 18 and 19 on the Pickup Feed Driver PCB)
Remedy: [Related parts] R1.00 - Harness connecting from the Pickup Feed Driver PCB (UN4/J1485) to the Left Deck Pickup Sensor, Left Deck Pull-Out Sensor and Left Deck Pickup Solenoid (PS54/J7053, PS58/J7049 and SL6/J8000) - Harness between the Pickup Feed Driver PCB (UN4/J1485) and the Left Deck Pickup Motor (M42/J7048) - Harness between the Pickup Feed Driver PCB (UN4/J1483) and the Secondary Transfer Roller Detachment Motor (M31/J7003) - Harness between the Pickup Feed Driver PCB (UN4/J1487) and the Cassette Vertical Path Motor (M39/J7527) - Harness between the Pickup Feed Driver PCB (UN4/J1483) and the Left Deck Vertical Path Motor (M41/J7526) - Left Deck Pickup Sensor (PS54) - Left Deck Pull-Out Sensor (PS58) - Left Deck Pickup Solenoid (SL6) - Left Deck Pickup Motor (M42) - Secondary Transfer Roller Detachment Motor (M31) - Cassette Vertical Path Motor (M39) - Left Deck Vertical Path Motor (M41) - Pickup Feed Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 260-2514-05

Description: Power supply error
Causes: The 5 V supply to the sensor or the 24 V supply to the fan, motor and solenoid was not detected. (Blowout of FU3, 5, 6, 29, 32 and 52 on the Pickup Feed Driver PCB)
Remedy: [Related parts] R1.00 - Harness between the Pickup Feed Driver PCB (UN4/J1494) and the Outer Delivery Sensor 2 (PS133/J8571) - Harness connecting from the Pickup Feed Driver PCB (UN4/J1408) to the Delivery Flapper Solenoid and Delivery Heat Fan 1 and 2 (SL2/J7029, FM10/J7161 and FM11/J7541) - Harness connecting from the Pickup Feed Driver PCB (UN4/J1414) to the Delivery Heat Fan 3 and 4 (FM12/J7542 and FM13/J7543) - Harness connecting from the Pickup Feed Driver PCB (UN4/J1405) to the Delivery Motor, Reverse Motor and Reverse Disengagement Motor (M37/J7002, M38/J7000 and M54/J7030) - Outer Delivery Sensor 2 (PS133) - Delivery Flapper Solenoid (SL2) - Delivery Heat Fan 1, 2, 3 and 4 (FM10, FM11, FM12 and FM13) - Delivery Motor (M37) - Reverse Motor (M38) - Reverse Disengagement Motor (M54) - Pickup Feed Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 260-2522-05

Description: Power supply error
Causes: The 12 V or 24 V supply to the Multi-purpose Tray Pickup Driver PCB was not detected. (Blowout of FU13, 24 and 25 on the Drum Driver PCB)
Remedy: [Related parts] R1.00 - Harnesses between the Drum Driver PCB (UN6/J1902 and J1925) and the Multi-purpose Tray Pickup Driver PCB (UN97/J1351 and J1350) - Multi-purpose Tray Pickup Driver PCB (UN97) - Drum Driver PCB (UN6) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 261-0301-05

Description: Power supply error
Causes: The 12 V supply to the Multi Deck was not detected. (Blowout of FU2 on the DC Controller PCB)
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN2/J1231), the Drawer Unit (J8240) and the Multi Deck - Multi Deck - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 261-0302-05

Description: Power supply error
Causes: The 24 V supply to the driver PCB or the 3.5K Deck was not detected. (Blowout of FU1 on the DC Controller PCB)
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1212) and the Pickup Feed Driver PCB (UN4/ J1486) - Harness between the DC Controller PCB (UN2/J1252) and the Developing Assembly Control PCB (UN96/J1308) - Harnesses connecting the DC Controller PCB (UN2/J1222), the Drawer Unit (J8023) and the Fixing Feed Driver PCB (UN5/J1510) - Harness between the DC Controller PCB (UN2/J1225) and the Drum Driver PCB (UN6/J1901) - Harness between the Drum Driver PCB (UN6/J1920) and the 3.5K Deck Lattice (J7515C) - Pickup Feed Driver PCB (UN4) - Developing Assembly Control PCB (UN96) - Fixing Feed Driver PCB (UN5) - Drum Driver PCB (UN6) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 261-0406-05

Description: Power supply error
Causes: The 24 V supply to the Developing Assembly Control PCB was not detected. (Blowout of FU9 on the DC Controller PCB)
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1201) and the Developing Assembly Control PCB (UN96/J1300) - Developing Assembly Control PCB (UN96) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES