Code: 002-0001-05

Description: Fixing Thermistor low temperature detection error
Causes: After the Fixing Heater was turned ON, the Fixing Film Unit Main Thermistor detected no temperature increase.
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1489) and the IH Power Supply PCB (UN30/ J501) - Harnesses connecting the IH Power Supply PCB (UN30/J510), the Drawer Unit (J8027) and the Main Heater (H4) - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Main Heater (H4) - Fixing Film Unit - IH Power Supply PCB (UN30) - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.

Code: 003-0001-05

Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Film Unit Main Thermistor detected an abnormally low temperature during print control.
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1489) and the IH Power Supply PCB (UN30/ J501) - Harnesses connecting the IH Power Supply PCB (UN30/J510), the Drawer Unit (J8027) and the Main Heater (H4) - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Main Heater (H4) - Fixing Film Unit - IH Power Supply PCB (UN30) - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.

Code: 004-0001-05

Description: Protection circuit error
Causes: Voltage error was detected while the IH Power Supply Relay was turned OFF.
Remedy: Replace the IH Power Supply PCB (UN30).

Code: 004-0201-05

Description: Protection circuit error
Causes: An error in temperature difference between the Fixing Film Unit Sub Thermistor 1 and 2 was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (N4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 004-0202-05

Description: Protection circuit error
Causes: An error in temperature difference between the Fixing Film Unit Main Thermistor and the Fixing Film Unit Sub Thermistor 1 was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1/2 (THM11/J7404 and THM13/J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 004-0203-05

Description: Protection circuit error
Causes: An error in temperature difference between the Fixing Film Unit Main Thermistor and the Fixing Film Unit Sub Thermistor 2 was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1/2 (THM11/J7404 and THM13/J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 004-0214-05

Description: Protection circuit error
Causes: It was detected that temperature difference between the Fixing Film Unit Thermistor (Front) and the Fixing Film Unit Thermistor (Rear) was 50 deg C or more.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1/2 (THM11/J7404 and THM13/J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.

Code: 004-0215-05

Description: Protection circuit error
Causes: It was detected that temperatures of the Fixing Film Unit Thermistor (Front) and the Fixing Film Unit Thermistor (Rear) have changed by 20 deg C or more while operating the Fixing Film.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1/2 (THM11/J7404 and THM13/J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.