Mã lỗi Canon iR Advance C9075 Pro — Trang 58/67
Description: Model mismatch error. An accessory that is not supported is connected.
Remedy: Check the configuration of accessories. The Staple Finisher B1 is connected to the IR ADV C9075.
Description: Model mismatch error. An accessory that is not supported is connected.
Remedy: Check the configuration of accessories. The Staple Finisher B1 is connected to the IR ADV C9065.
Description: Model mismatch error. An accessory that is not supported is connected.
Remedy: Check the configuration of accessories. The Staple Finisher B1 is connected to the IR ADV C9065.
Description: Model mismatch error. A Finisher that is not supported is connected.
Remedy: Check the configuration of accessories.
Description: PDL software failure. Initialization error
Remedy: 1. PDL reset processing 2. Power cycle (Power OFF/ON)
Description: PDL software failure. In case system fatal error such as initialization failure occurs
Remedy: 1. PDL reset processing 2. Power cycle (Power OFF/ON)
Description: PDL software failure. No response from PDL. In the case of no response from PDL due to Subbootable failure or no existence.
Remedy: 1. PDL reset processing 2. Power cycle (Power OFF/ON) 3. Main controller board connection check 4. Re-installation of firmware 5. Main controller board replacement
Description: PDL software failure. In case of discrepancy of the version between the control software in main unit and PDL control software.
Remedy: 1. PDL reset processing 2. Power cycle (Power OFF/ON) 3. System full-format and installation