Các lỗi thường gặp

Code :
  • Code: E202 0001
  • Description: CIS Unit HP error (outward)
  • Causes: CIS Unit did not move to HP even it moved backward. Reader HP Sensor error, Reader Motor error, CIS Unit error
  • Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
  • Code: E202 0002
  • Description: CIS Unit HP error (homeward)
  • Causes: CIS Unit did not move to HP even it moved forward. Reader HP Sensor error, Reader Motor error, CIS Unit error
  • Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
  • Code: E246 0000
  • Description: System error
  • Causes: System error
  • Remedy: Contact to the sales companies.
  • Code: E247 0000
  • Description: System error
  • Causes: System error
  • Remedy: Contact to the sales companies.
  • Code: E248 0001
  • Description: Error in access to backup data for Reader (reading error at power-on)
  • Causes: The Reader-related adjustment values could not be read.
  • Remedy: 1. Clear the backup RAM of RCON. Execute COPIER>FUNCTION>CLEAR>RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
  • Code: E350 0000
  • Description: System error
  • Causes: System error
  • Remedy: Contact to the sales companies.
  • Code: E351 0000
  • Description: System error
  • Causes: System error
  • Remedy: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
  • Code: E354 0000
  • Description: System error
  • Causes: System error.
  • Remedy: Contact to the sales companies.