Description: Card Reader communication error (serial communication)
Causes: Communication with the Card Reader could not be started at startup.
Remedy: 1. Check the connection of the Card Reader-F1, and turn OFF and then ON the main power switch. 2. Remove the Card Reader-F1. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER> FUNCTION> CLEAR> E719- CLR.
Causes: Communication error between the Engine Controller PCB and the Main Controller PCB occurred.