Description: The rotation of the following is faulty: power supply cooling fan 1, power supply cooling fan 2, controller cooling fan.
The fan stop signal has been detected for 5 sec or more after the power supply cooling fan 1 has gone on.
Remedy: Disconnect and then connect J505 of the DC controller PCB. Replace the power supply cooling fan 1. Replace the DC controller PCB.
Description: The rotation of the following is faulty: power supply cooling fan 1, power supply cooling fan 2, controller cooling fan.
The fan stop signal has been detected for 5 sec or more after the power supply cooling fan 2 has gone on.
Remedy: Disconnect and then connect J505 of the DC controller PCB. Replace the power supply cooling fan 2. Replace the DC controller PCB.
Description: The rotation of the following is faulty: power supply cooling fan 1, power supply cooling fan 2, controller cooling fan.
The fan stop signal of the controller cooling fan has been detected continuously for 16 sec.
Remedy: Disconnect and then connect J1028 of the main controller PCB. Replace the controller cooling fan. Replace the main controller PCB.
Description: The fixing heat discharge fan rotation is faulty.
The fan stop signal has been detected for 5 sec or more after the fixing heat discharge fan has gone on.
Remedy: Disconnect and then connect J503 of the DC controller PCB. Replace the fixing heat discharge fan. Replace the DC controller PCB.
Description: The pre-transfer charging assembly fan rotation is faulty.
The fan stop signal has been detected for 5 sec or more after the pre-transfer charging assembly fan has gone on.ulty.
Remedy: Disconnect and then connect J504 of the DC controller PCB. Replace the pre-transfer charging assembly fan. Replace the DC controller PCB.
Description: An HP detection error has occurred in relation to the fixing inlet sensor (fixing wrap jam detection).
The home position is not detected when he sensor is moved up/down (i.e., the sensor has not gone on).
Remedy: Disconnect and then connect J508, J552, and J553 of the DC controller PCB. Disconnect and then connect J4001 and J4002 of the fixing inlet sensor ascent/descent motor driver PCB; as necessary, replace the fixing inlet sensor ascent/ descent motor. Replace the fixing inlet sensor ascent/descent motor driver PCB.
Description: An HP detection error has occurred in relation to the fixing inlet sensor (fixing wrap jam detection).
The home position is not detected when the sensor is moved up/down (i.e., the sensor has not gone off).
Remedy: Disconnect and then connect J508, J552, and J553 of the DC controller PCB. Disconnect and then connect J4001 and J4002 of the fixing inlet sensor ascent/descent motor driver PCB; as necessary, replace the fixing inlet sensor ascent/ descent motor. Replace the fixing inlet sensor ascent/descent motor driver PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.