Description: The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor has exceeded 100 deg C, but does not reach 150 deg C within 2.5 min thereafter)
Remedy: Disconnect and then connect J508 of the DC controller PCB. Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor and the DC controller. Check the mounting/soiling of the main thermistor. Replace the fixing heater. Replace the AC driver PCB. Replace the DC controller PCB.
Code: E002-0010
Description: The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned on without resetting the error.
Remedy: Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E003-0000
Description: The fixing unit temperature is abnormally low. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor has exceeded 100 deg C, but is 70 deg C or less for 2 sec thereafter.
Remedy: Disconnect and then connect J508 of the DC controller PCB. Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor and the DC controller PCB. Check the mounting/soiling of the main thermistor. Replace the fixing heater. Replace the AC driver PCB. Replace the DC controller PCB.
Code: E004-0000
Description: The fixing unit has a fault. (protective circuit ON) After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
While the sub heater is on, the SSR for the heater drive has a short-circuit for 5 sec or more.
Remedy: Replace the AC driver PCB. Replace the DC controller PCB.
Code: E004-0001
Description: The fixing unit has a fault. (protective circuit ON) After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
While the main heater is on, the SSR for the heater drive has a short-circuit for 5 sec or more.
Remedy: Replace the AC driver PCB. Replace the DC controller PCB.
Code: E005-0000
Description: The fixing web has run out. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The absence of the fixing web has been detected for 5 sec or more.
Remedy: Check the position of the fixing web detecting lever. Replace the fixing web. Replace the fixing web length sensor. Replace the DC controller PCB. If you have replaced the fixing web, be sure to reset the counter: - COPIER>COUNTER>MISC>FIX-WEB - COPIER>COUNTER>DRBL-1>FX-WEB
Code: E005-0010
Description: The fixing web has run out. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then on without resetting the error.
Remedy: Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E010-0000
Description: The main motor rotation is faulty.
After the main motor has gone on, the FG signal of the motor is not detected for 2 sec or more.
Remedy: Disconnect and then connect J611 and J612 of the main motor. Disconnect and then connect J514 of the DC controller PCB. Disconnect and then connect J1720 of the relay PCB. Replace the main motor. Replace the relay PCB. Replace the DC controller PCB.