Description: The lamp inverter PCB is faulty. The reader controller PCB is faulty.
The lamp inverter PCB is found to have a fault.
Code: E225-0000
Description: The scanning lamp (xenon tube) is faulty. The inverter PCB is faulty. The CCD/AP PCB is faulty. The reader controller PCB is faulty.
A specific signal level cannot be attained by CCD gain correction at power-on.
Code: E225-0002
Description: The scanning lamp (xenon tube) is faulty. The inverter PCB is faulty. The CCD/AP PCB is faulty. The reader controller PCB is faulty.
The edge gain correction value changed more than a specific level compared with the correction value used for the preceding sheet.
Code: E240-0000
Description: The main controller PCB. The DC controller PCB is faulty.
An error has occurred in the communication between the main controller PCB and the CPU of the DC controller PCB.
Code: E240-010B
Description: The main controller PCB. The DC controller PCB is faulty.
An error occurred in the sequence during printing.
Code: E243-0000
Description: The control panel CPU PCB is faulty. The main controller PCB is faulty.
An error has occurred in communication between the CPU of the control panel CPU PCB and the main controller PCB.
Code: E248-0001
Description: The EEPROM on the reader controller PCB is faulty. The reader controller PCB is faulty.
The ID read into the EEPROM when the main power switch has been turned on and the ID in the ROM do not match.
Code: E248-0002
Description: The EEPROM on the reader controller PCB is faulty. The reader controller PCB is faulty.
When data is written into EEPROM, the data written and the data read do not match.