Description: There is a DDI communication error.
There is an SCI error. The reception data is faulty. A reception time-out condition has occurred. An SEQ timeout error has occurred. An SEQ time-out error has occurred.
Remedy: Disconnect and connect the DDI-S cable connector; then, as necessary, replace the reader controller PCB or the main controller PCB.
Description: The accessories board is of the wrong type.
At time of start-up, the UFR board is found to be of the wrong type. (A query is made to find out if the type is correct with reference to the engine ID.)
Remedy: Replace it with a UFR board of the correct type.
Description: The accessories board is of the wrong type.
At time of start-up, the scanner board is found to be of the wrong type. (A query is made to find out if the type is correct with reference to the engine ID.)
Remedy: Replace it with a scanner board of the correct type.
Description: There is an error in the ASIC for image processing or in the ASIC for memory control/communication control.
There is an error in IC1015 (ASIC for image processing) or in IC1012 (for memory control/communication control) on the main controller PCB. (e.g., image data transfer error)
Remedy: Turn off the main power, and check the main controller PCB; then, turn on the main controller PCB