Remedy: 1 After powering the printer OFF, then ON again, check whether the same error status will occur or not. (Repeatability check) 2 Replace the Controller (C495MAIN).
Description: Video related hardware error (including PWM IC calibration error)
Causes: • Controller (C495MAIN)
Remedy: 1 After powering the printer OFF, then ON again, check whether the same error status will occur or not. (Repeatability check) 2 Replace the Controller (C495MAIN).
Description: C1999 Other hardware error C2000 Software error
Causes: • Controller (C495MAIN)
Remedy: 1 After powering the printer OFF, then ON again, check whether the same error status will occur or not. (Repeatability check) 2 Replace the Controller (C495MAIN).
Description: Process Motor YMC error • When the printer is not put in a ready status if the predetermined time has elapsed at motor-on. • When the printer is put out of the ready status continuously for the predetermined time during motor rotation.
Causes: • PU Drive Motor Y/M/C (M4) • PU Drive Motor Bk (M5) • Control Board (PWB-A)
Remedy: 1 Check the motor connector connection status, and correct if it is improper. 2 Check the motor drive coupling status, and correct if it is improper. 3 Check the operation of M4. p115 PWB-A CNPM-A-5A(REM) 9-C 4 Replace the PWB-A.
Description: Process Motor K error • When the printer is not put in a ready status if the predetermined time has elapsed at motor-on. • When the printer is put out of the ready status continuously for the predetermined time during motor rotation.
Causes: • PU Drive Motor Y/M/C (M4) • PU Drive Motor Bk (M5) • Control Board (PWB-A)
Remedy: 1 Check the motor connector connection status, and correct if it is improper. 2 Check the motor drive coupling status, and correct if it is improper. 3 Check the operation of M5. p115 PWB-A CNPM-A-5B(REM) 12-H 4 Replace the PWB-A.
Description: Suction Fan Motor error When the lock signal is detected continuously for the predetermined time during fan rotation.
Causes: • Fuser Fan Motor (M7) • PH Fan Motor (M8) • Suction Fan Motor (M13) • Ozone Fan Motor (M9) • PS Fan Motor (M6) • PU Fan Motor (M12)
Remedy: 1 Check the motor connector connection status, and correct if it is improper. 2 Check the load status of the fan section, and correct if it is improper. 3 Check the operation of M13. p115 PWB-A CNF1-A-10(REM) 12-A 4 Replace the PWB-A.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.