Display: SERVICE CALL 00010007: CR MOTOR IN POSITION TIME OUT
Description: When be it locateds stable at the time of halt processing with the CR motor control, (the in position time) the position control inside period did not improve.
Remedy: • Tension adjustment of the n steel belt • CR encoder exchange • CR motor exchange • C362DRV board exchange.
Code: 00010008
Display: SERVICE CALL 00010008: SERVO INTERRUPTION WATCH DOG TIME OUT ERROR
Display: SERVICE CALL 0001000A: CR HOME POSITION DETECTION ERROR
Description: The carriage (CR_) HP detection sensor is abnormal.
Remedy: • Cleaning of the CR_HP detection sensor • Whether or not CR_HP detection sensor cable is jointed to the C362DRV board (CN43) confirmation CR_HP detection sensor exchange • CR_HP sensor exchange • C362DRV board exchange
Code: 0001000C
Display: SERVICE CALL 0001000C: HEAD SLIDE HOME POSITION DETECTION ERROR
Description: Head SLID starting point sensor failure
Remedy: It confirms whether the detection actuation such as the adhesion, dirt of ink are prevented in the sensor surface and be abnormal no and check the SLID starting point sensor, in the case that the error is not canceled. In the case that there is abnormality: • Cleaning of the SLID starting point detection sensor • Head SLID starting point detection sensor cable be confirmation whether or not it is jointed to the C362DRV board (CN52). • Head SLID starting point detection sensor exchange • C362DRV board exchangeg
Code: 0001000D
Display: SERVICE CALL 0001000D: COVER OPEN SENSOR ERROR (00)
Description: COVER OPEN SENSOR ERROR (00)
Remedy: The sensor attachment location of the 2 pieces of right and left are confirmed. In the case that the error is not canceled in spite of proper location the cover opening detection sensor is checked. In the case that there is abnormality: • It confirms whether n cover sensor cable is jointed to the C362DRV board (CN4/ 5). • Cover sensor exchange • C362DRV board exchange
Code: 0001000E
Display: SERVICE CALL 0001000E: COVER OPEN SENSOR ERROR (01)
Description: COVER OPEN SENSOR ERROR (01)
Remedy: The sensor attachment location of the 2 pieces of right and left are confirmed. In the case that the error is not canceled in spite of proper location the cover opening detection sensor is checked. In the case that there is abnormality: • It confirms whether n cover sensor cable is jointed to the C362DRV board (CN4/ 5). • Cover sensor exchange • C362DRV board exchange
Code: 0001000F
Display: SERVICE CALL 0001000F: CRMOTOR OVER HEAT (PWMOUTPUT MALFUNCTION)
Description: Load continues to be linked to the CR motor/PWM output abnormal
Remedy: • It confirms whether there are not a damage and dirt in the run on cursor, CR subordinate movement pulley, CR rail of n head Assy. • Steel belt tension confirmation/adjustment • CR motor exchange • C362DRV board exchange