Mã lỗi Epson Stylus Pro 10000CF — Trang 4/9
Code:
Tất cả lỗi (66)
00,010,015
00,010,016
00,010,017
00,010,018
00,010,019
00000100
00000101
00000102
00000103
00010000
00010001
00010002
00010003
00010004
00010005
00010006
00010007
00010008
00010009
0001000A
0001000C
0001000D
0001000E
0001000F
00010010
00010012
00010013
00010014
0001001A
0001001B
0001001C
0001001D
0001001E
00010020
00010021
00010022
00020000
00020001
00020002
00020003
00020004
00020005
00020006
0002000B
0002000C
00030015
00030016
00030017
00030018
00030019
0003001A
0003001B
0003XXXX
0100
0101
0102
0103
100000E0
10000100
10000180
100001A0
100005C0
10000XXX
D0090000
D0110013
D0XXXXXX
Display: SERVICE CALL 00010010: PF MOTOR OVER HEAT (PWM OUTPUT MALFUNCTION)
Description: Load continues to be linked to the PF motor/PWM output abnormal
Remedy: • PF timing belt tension confirmation/adjustment • PF roller and PF roller subordinate movement. • PF timing belt exchange • PF motor exchange • C362DRV board exchange
Display: SERVICE CALL 00010012: CAP HOME POSITION ERROR
Description: Starting point detection error or cap starting point sensor defective treatment by cap motor step-out
Remedy: • Cable splicing confirmation between the cap starting point sensor and CSCI board • Cleaning of the cap starting point sensor • Cleaning unit exchange
Display: SERVICE CALL 00010013: SUPPLY SYSTEM (INK PUMP) HOME POSITION ERROR
Description: It is defective the starting point detection error or supply system starting point sensor by the motor step-out of ink pump Assy.
Remedy: • Supply system motor exchange • Supply system starting point sensor exchange • C362DRV board exchange
Display: SERVICE CALL 00010014: PRESSURE DEFECTIVE ERROR
Description: It is defective the pressure detection error or pressure sensor by supply system motor step-out.
Remedy: • Regulator valve solenoid exchange • Supply system motor exchange • Sensor exchange • C362DRV board exchange
Display: OVERFLOW SERVICE CALL 0001001A: INK SURFACE SENSOR (Y) OVERFLOW
Description: Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
Remedy: • I/C valve solenoid exchange • C362DRV board exchange • Surface of a liquid sensor exchanger
Display: SERVICE CALL 0001001B: HEAD DRIVER (TG) TEMPERATURE ERROR
Description: Head failure or head cable splicing defective/breaking of wire
Remedy: • Head cable joint • Head Assy exchange
Display: SERVICE CALL 0001001C: SUCTION FAN HOME POSITION ERROR
Description: Starting point detection error or shutter starting point sensor defective o treatment by shutter motor step-out.
Remedy: • Adsorption fan shutter motor exchange • C362DRV board exchange • Shutter starting point sensor exchange
Display: SERVICE CALL 0001001D: CR SERVO PARAMETER ERROR
Description: Load continues to be linked to the CR motor. /CR motor defective.
Remedy: • Do the same correspondence as service call 00010004.