Các lỗi thường gặp

Code :
  • Code: 00020004
  • Display: SERVICE CALL 00020004: ASIC INJUSTICE VERSION ERROR
  • Description: The ASIC version on the C362DRV board is not correct.
  • Remedy: • C362DRV board exchange
  • Code: 00020005
  • Display: SERVICE CALL 00020005: FIRMWARE ASIC MISMATCHING
  • Description: ASIC and firmware on the C362DRV board are not corresponding.
  • Remedy: • Exchange the C362DRV board, whether or not n correct firmware is installed.
  • Code: 00020006
  • Display: SERVICE CALL 00020006: FIRMWARE BSIC MISMATCHING
  • Description: ASIC and firmware on the C362DRV board are not corresponding.
  • Remedy: • Exchange the C362DRV board, whether or not n correct firmware is installed.
  • Code: 0002000B
  • Display: SERVICE CALL 0002000B: MEMORY INSUFFICIENT ERROR
  • Description: Faulty of the program
  • Remedy: • Program retouch necessary
  • Code: 0002000C
  • Display: SERVICE CALL 0002000C: REVIEW ERROR
  • Description: The Dip-SWbinding on the C362DRV board is not in accord with a program version.
  • Remedy: • Dip-SWbinding modification or correct program are installed.
  • Code: 00030015
  • Display: SERVICE CALL 00030015: INK SUPPLY DEFECTIVE (K)
  • Description: Even if Isupply it ink the surface of a liquid sensor does not become full. It does not become defective (on I/C valve solenoid) or the surface of a liquid sensor defective
  • Remedy: • I/C valve solenoid exchange • C362DRV board exchange • Surface of a liquid sensor exchange
  • Code: 00030016
  • Display: SERVICE CALL 00030016: INK SUPPLY DEFECTIVE (C)
  • Description: Even if Isupply it ink the surface of a liquid sensor does not become full. It does not become defective (on I/C valve solenoid) or the surface of a liquid sensor defective
  • Remedy: • I/C valve solenoid exchange • C362DRV board exchange • Surface of a liquid sensor exchange
  • Code: 00030017
  • Display: SERVICE CALL 00030017: INK SUPPLY DEFECTIVE (M)
  • Description: Even if Isupply it ink the surface of a liquid sensor does not become full. It does not become defective (on I/C valve solenoid) or the surface of a liquid sensor defective
  • Remedy: • I/C valve solenoid exchange • C362DRV board exchange • Surface of a liquid sensor exchange