Causes: Positions of the ink system components do not match with the sensor condition. • Connection failure of the sensor • Sensor failure • IS Unit failure
Remedy: 1. Replace the Wiper and Cap Sensor. 2. Replace the IS Unit HP Sensor. 3. Replace the IS Unit.
Causes: 1. The Ink Selector Motor or the Ink Selector Sensor is not connected correctly. 2. Connection between the SUB Board and the Main Board has an abnormality. 3. Ink selection is not completed after the specified time has passed. • Ink Selector Motor failure • Ink Selector Sensor failure
Causes: 1. Connection failure of the APG Sensor. 2. When PG is being adjusted, the APG Sensor cannot detect its origin. • APG Sensor failure • APG Motor failure
Remedy: 1. Replace the APG Sensor. 2. Replace the APG Motor Assy.
Causes: 1. Connection failure of the APG Motor. 2. The electric current flowing when driving the motor is irregularly large. • APG Motor Assy cable is damaged. • Irregular load • APG Motor Assy encoder failure • APG Motor failure