Causes: 1. Connection failure of the Release Sensor. 2. Cannot detect the switching operation status of the driven roller. • Release Sensor failure • Release Motor failure
Remedy: 1. Replace the Release Sensor. 2. Replace the Release Motor Assy.
Code: 153A
Description: Release Motor overload error
Causes: The electric current flowing when driving the motor is irregularly large. • Release Motor Assy cable is damaged. • Irregular load • Release Motor Assy encoder failure • Release Motor failure
Remedy: Replace the Release Motor Assy.
Code: 153B
Description: Release Motor over speed error
Causes: Detects that it is being driven at an irregularly faster speed than the specified value just before stopping. • Irregular load • Release Motor Assy encoder failure • SUB Board is damaged. • Release Motor driver failure
Remedy: 1. Replace the Release Motor Assy. 2. Replace the SUB-C Board. 3. Replace the Main Board.
Code: 153C
Description: Release Motor reversing error
Causes: Detects accumulatively more than the specified number of times that it is being driven in the opposite direction to the specified driving direction. • The polarity of Release Motor Assy cable is opposite. • Release Motor Assy encoder failure
Remedy: Replace the Release Motor Assy.
Code: 153D
Description: Release Motor driving time-out error
Causes: Detects that the driving period is irregularly long. • Irregular load • Firmware becomes out of control.
Remedy: Replace the Main Board.
Code: 153E
Description: Release Motor velocity deviation error
Causes: 1. Connection failure of the Release Sensor. 2. Detects, when accelerating/decelerating the motor, that it is being driven at an irregularly faster speed than the specified value. • Irregular load • Release Motor Assy encoder failure • Release Motor failure • SUB Board is damaged. • Release Motor driver failure
Remedy: 1. Replace the Release Motor Assy. 2. Replace the SUB-B Board. 3. Replace the Main Board.
Code: 153F
Description: Release Motor lock error
Causes: 1. Connection failure of the Release Motor. 2. Connection failure of the Release Encoder. 3. Connection between the SUB-C Board and the Main Board has an abnormality. 4. Detects that it is being driven at an irregularly slower speed than the specified value. • Irregular load • Release Encoder failure • Release Motor failure
Remedy: Replace the Release Motor Assy.
Code: 1540
Description: Cutter HP Sensor detection error
Causes: The home position of the Cutter is not detected. • Operation failure due to paper jam • Cutter HP Sensor failure • Cutter Motor Assy failure
Remedy: 1. Replace the Cutter HP Sensor. 2. Replace the Cutter Motor Assy.