Mã lỗi Epson Stylus Pro 4910 — Trang 18/18
Description: NVRAM error
Causes: NVRAM erase or write error has occurred.
Remedy: Replace the Main Board.
Description: SDRAM error
Causes: Any value cannot be input when accessing SDRAM to write the value.
Remedy: Replace the Main Board.
Description: FLASH BOOT SUM CHECK error
Causes: 1. Installation of the firmware has been failed. 2. The Flash ROM is damaged.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.
Description: F/W load error
Causes: Reading/decompressing the firmware has been failed.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.
Description: System interrupt watchdog time-out error
Causes: A system failure such as CPU failure, defective cash or the like has occurred.
Remedy: Replace the Main Board.
Description: AC shut-off
Causes: The AC power has been shut off due to a power failure, unplugged, Power Supply Board failure, or Main Board failure or the like.
Remedy: 1. Replace the Power Supply Board. 2. Replace the Main Board.
Description: Service call for FW debugging
Causes: This is an error for debugging in the design stage. However, it may occur due to unexpected reasons such as external noises.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.
Description: CPU related service call
Causes: • The firmware has a defect. • The Main Board is broken.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.