Causes: 1. During detection of paper thickness, the thickness cannot be determined because the sensor is not stable due to vibration or the like. 2. The Paper Thickness Sensor is damaged and cannot detect the paper thickness correctly.
Causes: The electric current flowing when driving the motor is irregularly large. • Decompression Pump cable is damaged. • Irregular load • Decompression Pump encoder failure • Decompression Pump failure
Causes: Detects that it is being driven at an irregularly faster speed than the specified value just before stopping. • Irregular load • Decompression Pump encoder failure • SUB Board is damaged. • Decompression Pump driver failure
Remedy: 1. Replace the Decompression Pump. 2. Replace the SUB-B Board. 3. Replace the Main Board.
Causes: Detects accumulatively more than the specified number of times that it is being driven in the opposite direction to the specified driving direction. • The polarity of Decompression Pump Assy cable is opposite. • Decompression Pump Assy encoder failure
Causes: Detects, when accelerating/decelerating the motor, that it is being driven at an irregularly faster speed than the specified value. • Irregular load • Decompression Pump Assy encoder failure • Decompression Pump failure • SUB Board is damaged. • Decompression Pump driver failure
Remedy: 1. Replace the Decompression Pump. 2. Replace the SUB-B Board. 3. Replace the Main Board.
Causes: 1. Connection failure of the Decompression Pump Assy. 2. Detects that it is being driven at an irregularly slower speed than the specified value. • Irregular load • Decompression Pump Assy encoder failure • Decompression Pump failure