Description: Pre Heater power supply abnormal error 1
Cable disconnection, breaking, blowout of a fuse, or heater failure.
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the Pre Heater.
Code: 1935
Description: HTC common power supply abnormal error 2
Abnormal temperature (the heater is not heated).
Remedy: 1. Reconnect the thermistor. 2. Replace the Sub-E Board.
Code: 1940
Description: Platen Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor . 2. Replace the Main Board.
Code: 1942
Description: Platen Heater overheat error
A heater temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor . 2. Replace the Platen Heater. 3. Replace the Main Board.
Code: 1943
Description: Platen Heater heat deviation error
The difference between the current temperature and target temperature exceeded a predetermined limit.
Remedy: 1. Replace the thermistor . 2. Replace the Platen Heater. 3. Replace the Main Board.
Code: 1944
Description: Platen Heater power supply abnormal error 1
Cable disconnection, breaking, blowout of a fuse, or heater failure.
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the Platen Heater.
Code: 1945
Description: Platen Heater power supply abnormal error 2
Disconnection or break of the cables, blowout of a fuse, or heater failure
Remedy: 1. Connect the cables correctly. 2. Replace the cables. 3. Replace the SUB-E Board. 4. Replace the Platen Heater.
Code: 1950
Description: After Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor (After Heater). 2. Replace the Main Board.